Wind Turbine FAQs

  • Summary Checklist for Your Choice

    Choose the SR or ST-1200W if you want portability, low noise, and minimal investment for camping or caravans.

    Choose the ST-2000, ST-3000, or ST-5000 if you have a stationary house/cabin and want to supplement solar panels at night.

    Choose the ST-10kW or 20kW if you have heavy agricultural power needs, acreage, and a budget for proper mast engineering.

    The vertical axis wind turbines listed on the BushLine Outdoor Equipment catalog are categorized by physical design shapes, which dictate their ideal applications.

  • No.Wind turbines generate "wild" 3-phase AC power that changes voltage constantly with the wind speed. Connecting it directly to a battery or a standard solar inverter will instantly destroy your equipment. Youmustwire the turbine into a dedicatedWind/Solar Hybrid MPPT Controller with an integrated Dump Load Resistor. The controller converts the power to stable DC to charge your batteries safely.

  • You must match the turbine and its hybrid controller to the exact voltage of your existing battery bank:

    • 12V: Best for compact mobile setups like caravans, 4WDs, and camper trailers.
    • 24V: Great for medium-sized setups like off-grid sheds, cabins, and motorhomes.
    • 48V: The gold standard for full off-grid home systems. Higher voltage means less energy loss through your wires and allows you to use thinner, safer cables.
  • When your battery bank becomes 100% fully charged, it stops accepting power. If a heavy wind storm hits at night when your batteries are full, a turbine with nowhere to send its power will "free-spin" out of control and physically fly apart. A hybrid controller fixes this by automatically diverting that excess power into the dump load resistor, which burns it off safely as heat and acts as an electronic brake to slow the turbine down.

  • No,that is the main benefit of the vertical design. Traditional horizontal "propeller" turbines create a high-pitched, annoying "chopping" noise. Our ST Tulip and Flower series utilise advanced omnidirectional maglev-style bearings, making them virtually silent and completely vibration-free, all you will hear is the wind. They are perfect for suburban blocks, tight caravan parks, and areas close to neighbours.

  • Yes.These turbines have an incredibly low startup wind speed of just 2.0 m/s, meaning the blades will begin rotating in a very gentle breeze. However, please note that physical power generation only starts accumulating once wind speeds consistently clear 4 to 5 m/s.

  • You should connect the wind turbine to a battery bank first, via a dedicated charge controller, rather than directly to an inverter. Connecting a wind turbine directly to a standard inverter will damage the equipment or cause the system to fail.

    🔋 The Correct Wiring SequenceTo safely capture and use the power, your setup must follow this exact order:

    1. Wind Turbine: Generates wild, fluctuating 3-phase AC power as wind speeds change.
    2. Hybrid/Wind Charge Controller: Converts the unstable AC power into steady DC power. It also protects the turbine from over-speeding by applying an electronic brake during high winds.
    3. Battery Bank (12V/24V/48V): Acts as a buffer to store the energy. It absorbs sudden power spikes from wind gusts and provides a steady source of energy.
    4. Off-Grid Inverter: Connects to the battery, converting the stored DC battery power into standard AC power for your household appliances.

    ⚠️ Why You Cannot Skip the Battery

    • Unstable Voltage: Wind speeds change second by second. Without a battery to absorb and smooth out these massive fluctuations, a direct-connect inverter would constantly turn off and error out.
    • Turbine Destruction: When a battery is full or disconnected, a wind turbine loses its "load" (resistance). Without that resistance, the blades can spin out of control in high winds and physically destroy the unit. The charge controller uses the battery connection to safely dump excess power and slow the turbine down.
  • Wiring & Installation Requirement:This wind turbine generates 3-phase AC power andcannotbe connected directly to a battery, solar controller, or home inverter. To operate safely, it must run through a dedicatedWind/Solar Hybrid MPPT Controller with an integrated Dump Load Resistor. The dump load prevents the turbine from over-speeding and destroying itself in high winds once your batteries are fully charged.

  • It is almost always caused by one of three common installation errors. Check these variables in order: Checking the Multi-Meter Setting (Most Common Mistake)

    • The Issue: The customer is likely measuring the three wires coming out of the turbine using a DC voltage setting on their multimeter.
    • The Reality: Wind turbines generate 3-Phase AC power directly from the stator.
    • The Fix: Instruct them to switch their multi-meter to AC Voltage (V~). Testing the wires under a DC setting will provide a false, completely inaccurate reading near zero.

    2. The Turbine is Stalling Due to Incorrect Wiring

    • The Issue: The turbine blades are spinning heavily but turning very slowly or locking up because of an electrical short.
    • The Reality: If any of the three AC output wires are accidentally touching each other, or if the controller's internal braking diodes have short-circuited, it creates a magnetic brake. This bogs down the turbine, physically stopping it from spinning fast enough to build voltage.
    • The Fix: Have them completely disconnect the turbine from the controller. If the turbine suddenly unbogs and spins much faster when disconnected, the problem is a short circuit in the wiring or a faulty controller.

    3. Voltage Drop Caused by Thin Cables

    • The Issue: The customer ran thin wiring over a long distance from the tower down to the battery shed.
    • The Reality: If they used standard thin solar cables or thin automotive wire over a long distance (e.g., 20+ metres), the natural resistance of the copper wire will choke out the electricity. The energy is lost as heat inside the wire before it ever reaches the meter.
    • The Fix: Ensure they are using heavy-duty, minimum 8 AWG or 6 AWG thick cable lines between the mast and the controller house
  • Wind turbines are rated byCumulative Daily Capacity, not instantaneous hourly peak output. Because wind speeds fluctuate constantly second-by-second, a 1200W turbine is designed to yield up to 1200W of total poweraccumulated over a 24-hour periodin optimal conditions (averaging roughly 50W per hour). This constant, steady trickle is exactly what makes vertical turbines perfect for maintaining batteries overnight when solar panels are offline.

  • Not necessarily — this is one of the most common questions we get, and it's rarely a faulty unit. It's usually a quick settings check, or (on a first-time install) how the wiring and start-up sequence were done. See our full Wind Turbine 0W Troubleshooting & Installation Guide for the complete walkthrough, or contact us and we'll help you sort it out.
  • Short Answer Wire your bus bar and breakers before and after the controller, then power up in the right order — battery first, then solar, then wind. Getting this sequence right prevents almost all wiring issues, including the common "spinning but 0W" problem. Answer (rich text field, with the link placeholder): Correct installation comes down to isolation and the right sequence: Fit a breaker before the controller (turbine/solar side) and after it (battery side), landing on a DC bus bar Keep the turbine-to-controller cable run to 2–10 metres to limit voltage drop Power up in this order: battery breaker first, then solar, then wind turbine last See our full How to Install & Start Up guide for the complete step-by-step walkthrough and wiring diagram.

Solar photovoltaic PV Combiner Box With Lightning Protection 2 in 1 out

Regular price $149.99 AUD
Configuration

Tracking

Keep an eye on your gear.

Simply enter the tracking number sent to your email to see exactly where your package is and when it is estimated to arrive.

Note: It may take 24-48 hours for tracking information to update after your order has been dispatched.

Track My Order

Delivery and Shipping

At Bushline, we believe getting your gear should be easy. That is why we offer Free Standard Shipping to every customer in Australia and New Zealand. No minimum spend, no surcharges.

How Long It Takes

We quote these times from the day you place your order, not from the day we dispatch it. That is the number that actually matters to you, and quoting it any other way just moves the goalposts.

  • Most gear: 10 to 14 days from the day you order. Allow up to 3 weeks.
  • New Zealand: Same as above. NZ orders run to the same timeframe as Australian ones.
  • Large wind turbines: Allow up to 5 weeks. These are heavy, oversized units and they travel on slower freight than everything else.
  • Regional & remote areas: Please allow extra time on top of the above.

Dispatch & Tracking

  • Pick & Pack: We aim to dispatch within one business day (Monday to Friday). Most orders go out within two.
  • Weekends: Orders placed on weekends or public holidays are processed the next business day.
  • Tracking: You will get a Shipping Confirmation email with your tracking number as soon as your order ships.

If Your Order Is Running Late

Ring 0400 333 898 or email Support@BushLine.com.au and we will chase the tracking ourselves rather than sending you off to do it. You will get a straight answer on where it is, including if it has not moved.

Need A Large Turbine Sooner?

Expedited freight is available on the big units at extra cost, which brings delivery down to roughly a fortnight. It is quoted per order because it depends on the size of the unit and where it is going. Get in touch before you order and we will price it for you.

Rated 600V at the breaker, not 1000V at the fuse.

Two strings of panels coming back to one controller means two positives and two negatives arriving at a terminal built for one pair. Most people twist them together under a lug in a plastic box and it works fine — right up until a fault in one string back-feeds down the other, or a storm drops a surge into forty metres of DC cable strung across an open paddock and pushes it straight into the controller input.

A combiner box is the fix for both. This one takes two string inputs and gives you one output. Each string gets its own fuse holder with a 15A fuse in it, so a faulty string opens its own fuse instead of drawing current back from the good one. The output side carries a 2-pole DC 600V/63A MCB, so you can isolate the whole array under load before you touch the controller. Alongside it sits a 2-pole DC 600V surge protective device, wired to shunt a lightning-induced surge to earth rather than let it travel on to your gear.

Be careful with the voltage on this one, because the supplier has not been straight about it. The fuse holder is a 1000V part, but the MCB and the SPD are both 600V DC. The lowest-rated component in the chain sets the limit for the box, so the real ceiling here is 600V DC — not 1000V. No overall system voltage figure was supplied, so we are not going to publish one. Work out your array's open-circuit voltage at the coldest morning you get, and if it lands anywhere near 600V, this is not your box. Enclosure material, external dimensions, mounting method and cable gland sizes were not specified either.

What It Solves
  • Two strings, one input: your controller has one PV input pair and you have two strings to land on it.
  • Long runs in open country: a bore pump array sitting 40 metres from the shed, with nothing between the panels and the controller but cable and weather.
  • Storm season on a farm: a nearby strike doesn't need to hit the panels to induce a surge in the DC run — the SPD gives that energy somewhere to go.
  • Isolating before you work: the 63A breaker lets you shut the array down at one handle instead of pulling connectors under load.
  • Shack or remote hut arrays: ground-mount panels at a bush block where you want the fusing and the isolator in one weatherproof box, not spread across three.
Key Features
  • Two in, one out: two string inputs combined to a single output pair. One configuration only — there is no larger version of this listing.
  • Per-string fusing: a 1000V-rated fuse holder on each string, supplied with a 15A fuse fitted.
  • DC-rated breaker: 2-pole DC 600V/63A MCB on the output, so both poles break together.
  • Surge protection: 2-pole DC 600V SPD to divert lightning-induced surges away from the controller.
  • 600V is the real limit: the breaker and SPD are 600V DC parts, so size your string voltage to 600V, not to the fuse holder's 1000V marking.
  • Weatherproof enclosure: supplier copy states IP65. We have not sighted a test report, so treat it as the supplier's claim.
  • DC parts, not AC parts: DC arcs don't self-extinguish the way AC does — the breaker and SPD in here are DC-rated, which an AC consumer-unit breaker is not.
  • Everything in one box: fusing, isolation and surge protection in a single enclosure instead of three separate boxes on the wall.
  • SPD needs an earth: a surge protector only works if its earth terminal is bonded to a proper earth. Without that it does nothing.
Where This Fits

This is one part of the gear that sits between a wind turbine and your battery bank. Here's the whole picture:

Off-grid wiring layout — vertical axis wind turbine and solar panel into a hybrid MPPT controller, with dump load, main battery circuit breaker, DC bus bar, 12V 24V 48V battery bank and inverter

  • Wind turbines: vertical axis turbines from 1kW to 20kW — quiet enough to put near the house, and they charge overnight when your solar can't.
  • Hybrid MPPT controllers: you can't wire a turbine straight to a battery. The controller rectifies the output, manages the charge, and brakes the turbine when the bank is full.
  • The rest of the electrical range: bus bars, breakers, isolators, cable, lugs and Anderson plugs.

Every input and output wants a breaker or isolator on it, so you can safely shut down and isolate the turbine before you touch anything. That protects you, and it stops a surge damaging your new turbine or the rest of your power system. Cable sizing depends on your run length, voltage and current — if you're building 12V or 24V, check the sizing against your own run or ask your sparky.

Q & A

Can I run a 1000V string through this because the fuse holder says 1000V?

No. The fuse holder is a 1000V part, but the MCB and the SPD next to it are 600V DC. The lowest-rated component sets the limit for the whole box, so 600V DC is the ceiling. The supplier never published an overall system voltage rating for the box, which is why you won't find one in our spec table. Calculate your array's open-circuit voltage at your coldest expected temperature and keep it comfortably under 600V, or pick a box with a stated 1000V rating throughout.

How many panels can I put on each input?

The fusing is 15A per string, so the panel short-circuit current for one string needs to sit below that with margin — most single strings of standard panels do. The number of panels in series is limited by voltage, not current, and that's the 600V figure above. Series count and voltage is the calculation that matters here.

Does the surge protector work on its own?

No. An SPD diverts surge energy to earth, so it only does its job if the earth terminal is bonded to a real earth electrode. Wire it into a box with no earth connection and you have a component that looks like protection and isn't.

Can I mount it outside on a pole or a shed wall?

Supplier copy says IP65, which would suit an outdoor wall. We have not sighted a test report and the mounting arrangement, enclosure material and gland sizes were not specified, so if it's going somewhere exposed, check the box in hand before you drill.

Do I need a licensed electrician for this?

PV work in Australia is regulated and the rules vary by state and by whether the system is grid-connected. Talk to a licensed sparky before you wire an array, particularly around earthing the SPD. Advice above is general and not a substitute for that.

What's actually in the box when it arrives?

One enclosure with two fuse holders and 15A fuses fitted, a 2-pole DC 600V/63A MCB and a 2-pole DC 600V SPD. Cable, glands beyond what is fitted, connectors and the earth conductor are not listed as included.

Specs

Specification Detail
Configuration 2 string inputs, 1 output (only configuration sold)
Maximum system voltage Not specified by supplier — the 600V DC MCB and 600V DC SPD are the limiting components, so treat 600V DC as the ceiling
Fuse holder rating 1000V rated holder (higher than the rest of the box — not the system limit)
Fuse fitted 15A per string
Circuit breaker (MCB) 2-pole, DC 600V, 63A
Surge protective device (SPD) 2-pole, DC 600V
SPD class / discharge current Not specified by supplier
Fuse type and size Not specified by supplier
Ingress protection IP65 stated in supplier copy; no test report sighted
Enclosure material Not specified by supplier
Enclosure dimensions Not specified by supplier
Cable gland size Not specified by supplier
Terminal / conductor capacity Not specified by supplier
Mounting method Not specified by supplier
Weight Not specified by supplier
Operating temperature range Not specified by supplier
Certification Not specified by supplier
Delivery Free delivery to Australia and New Zealand, no minimum spend. 10 to 14 days from order date, allow up to 3 weeks

Watch Me

No video for this one yet. If you want to see it working before you buy, email help@bushline.com.au and we'll get footage up.

Payment & Security

Payment Methods

  • American Express
  • Apple Pay
  • Google Pay
  • Mastercard
  • PayPal
  • Visa

Your payment information is processed securely.

We do not store credit card details or have access to your credit card information.

Wind Turbine FAQs

  • Summary Checklist for Your Choice

    Choose the SR or ST-1200W if you want portability, low noise, and minimal investment for camping or caravans.

    Choose the ST-2000, ST-3000, or ST-5000 if you have a stationary house/cabin and want to supplement solar panels at night.

    Choose the ST-10kW or 20kW if you have heavy agricultural power needs, acreage, and a budget for proper mast engineering.

    The vertical axis wind turbines listed on the BushLine Outdoor Equipment catalog are categorized by physical design shapes, which dictate their ideal applications.

  • No.Wind turbines generate "wild" 3-phase AC power that changes voltage constantly with the wind speed. Connecting it directly to a battery or a standard solar inverter will instantly destroy your equipment. Youmustwire the turbine into a dedicatedWind/Solar Hybrid MPPT Controller with an integrated Dump Load Resistor. The controller converts the power to stable DC to charge your batteries safely.

  • You must match the turbine and its hybrid controller to the exact voltage of your existing battery bank:

    • 12V: Best for compact mobile setups like caravans, 4WDs, and camper trailers.
    • 24V: Great for medium-sized setups like off-grid sheds, cabins, and motorhomes.
    • 48V: The gold standard for full off-grid home systems. Higher voltage means less energy loss through your wires and allows you to use thinner, safer cables.
  • When your battery bank becomes 100% fully charged, it stops accepting power. If a heavy wind storm hits at night when your batteries are full, a turbine with nowhere to send its power will "free-spin" out of control and physically fly apart. A hybrid controller fixes this by automatically diverting that excess power into the dump load resistor, which burns it off safely as heat and acts as an electronic brake to slow the turbine down.

  • No,that is the main benefit of the vertical design. Traditional horizontal "propeller" turbines create a high-pitched, annoying "chopping" noise. Our ST Tulip and Flower series utilise advanced omnidirectional maglev-style bearings, making them virtually silent and completely vibration-free, all you will hear is the wind. They are perfect for suburban blocks, tight caravan parks, and areas close to neighbours.

  • Yes.These turbines have an incredibly low startup wind speed of just 2.0 m/s, meaning the blades will begin rotating in a very gentle breeze. However, please note that physical power generation only starts accumulating once wind speeds consistently clear 4 to 5 m/s.

  • You should connect the wind turbine to a battery bank first, via a dedicated charge controller, rather than directly to an inverter. Connecting a wind turbine directly to a standard inverter will damage the equipment or cause the system to fail.

    🔋 The Correct Wiring SequenceTo safely capture and use the power, your setup must follow this exact order:

    1. Wind Turbine: Generates wild, fluctuating 3-phase AC power as wind speeds change.
    2. Hybrid/Wind Charge Controller: Converts the unstable AC power into steady DC power. It also protects the turbine from over-speeding by applying an electronic brake during high winds.
    3. Battery Bank (12V/24V/48V): Acts as a buffer to store the energy. It absorbs sudden power spikes from wind gusts and provides a steady source of energy.
    4. Off-Grid Inverter: Connects to the battery, converting the stored DC battery power into standard AC power for your household appliances.

    ⚠️ Why You Cannot Skip the Battery

    • Unstable Voltage: Wind speeds change second by second. Without a battery to absorb and smooth out these massive fluctuations, a direct-connect inverter would constantly turn off and error out.
    • Turbine Destruction: When a battery is full or disconnected, a wind turbine loses its "load" (resistance). Without that resistance, the blades can spin out of control in high winds and physically destroy the unit. The charge controller uses the battery connection to safely dump excess power and slow the turbine down.
  • Wiring & Installation Requirement:This wind turbine generates 3-phase AC power andcannotbe connected directly to a battery, solar controller, or home inverter. To operate safely, it must run through a dedicatedWind/Solar Hybrid MPPT Controller with an integrated Dump Load Resistor. The dump load prevents the turbine from over-speeding and destroying itself in high winds once your batteries are fully charged.

  • It is almost always caused by one of three common installation errors. Check these variables in order: Checking the Multi-Meter Setting (Most Common Mistake)

    • The Issue: The customer is likely measuring the three wires coming out of the turbine using a DC voltage setting on their multimeter.
    • The Reality: Wind turbines generate 3-Phase AC power directly from the stator.
    • The Fix: Instruct them to switch their multi-meter to AC Voltage (V~). Testing the wires under a DC setting will provide a false, completely inaccurate reading near zero.

    2. The Turbine is Stalling Due to Incorrect Wiring

    • The Issue: The turbine blades are spinning heavily but turning very slowly or locking up because of an electrical short.
    • The Reality: If any of the three AC output wires are accidentally touching each other, or if the controller's internal braking diodes have short-circuited, it creates a magnetic brake. This bogs down the turbine, physically stopping it from spinning fast enough to build voltage.
    • The Fix: Have them completely disconnect the turbine from the controller. If the turbine suddenly unbogs and spins much faster when disconnected, the problem is a short circuit in the wiring or a faulty controller.

    3. Voltage Drop Caused by Thin Cables

    • The Issue: The customer ran thin wiring over a long distance from the tower down to the battery shed.
    • The Reality: If they used standard thin solar cables or thin automotive wire over a long distance (e.g., 20+ metres), the natural resistance of the copper wire will choke out the electricity. The energy is lost as heat inside the wire before it ever reaches the meter.
    • The Fix: Ensure they are using heavy-duty, minimum 8 AWG or 6 AWG thick cable lines between the mast and the controller house
  • Wind turbines are rated byCumulative Daily Capacity, not instantaneous hourly peak output. Because wind speeds fluctuate constantly second-by-second, a 1200W turbine is designed to yield up to 1200W of total poweraccumulated over a 24-hour periodin optimal conditions (averaging roughly 50W per hour). This constant, steady trickle is exactly what makes vertical turbines perfect for maintaining batteries overnight when solar panels are offline.

  • Not necessarily — this is one of the most common questions we get, and it's rarely a faulty unit. It's usually a quick settings check, or (on a first-time install) how the wiring and start-up sequence were done. See our full Wind Turbine 0W Troubleshooting & Installation Guide for the complete walkthrough, or contact us and we'll help you sort it out.
  • Short Answer Wire your bus bar and breakers before and after the controller, then power up in the right order — battery first, then solar, then wind. Getting this sequence right prevents almost all wiring issues, including the common "spinning but 0W" problem. Answer (rich text field, with the link placeholder): Correct installation comes down to isolation and the right sequence: Fit a breaker before the controller (turbine/solar side) and after it (battery side), landing on a DC bus bar Keep the turbine-to-controller cable run to 2–10 metres to limit voltage drop Power up in this order: battery breaker first, then solar, then wind turbine last See our full How to Install & Start Up guide for the complete step-by-step walkthrough and wiring diagram.

Compare /10

Loading...