Wind Turbine FAQs

  • Summary Checklist for Your Choice

    Choose the SR or ST-1200W if you want portability, low noise, and minimal investment for camping or caravans.

    Choose the ST-2000, ST-3000, or ST-5000 if you have a stationary house/cabin and want to supplement solar panels at night.

    Choose the ST-10kW or 20kW if you have heavy agricultural power needs, acreage, and a budget for proper mast engineering.

    The vertical axis wind turbines listed on the BushLine Outdoor Equipment catalog are categorized by physical design shapes, which dictate their ideal applications.

  • No.Wind turbines generate "wild" 3-phase AC power that changes voltage constantly with the wind speed. Connecting it directly to a battery or a standard solar inverter will instantly destroy your equipment. Youmustwire the turbine into a dedicatedWind/Solar Hybrid MPPT Controller with an integrated Dump Load Resistor. The controller converts the power to stable DC to charge your batteries safely.

  • You must match the turbine and its hybrid controller to the exact voltage of your existing battery bank:

    • 12V: Best for compact mobile setups like caravans, 4WDs, and camper trailers.
    • 24V: Great for medium-sized setups like off-grid sheds, cabins, and motorhomes.
    • 48V: The gold standard for full off-grid home systems. Higher voltage means less energy loss through your wires and allows you to use thinner, safer cables.
  • When your battery bank becomes 100% fully charged, it stops accepting power. If a heavy wind storm hits at night when your batteries are full, a turbine with nowhere to send its power will "free-spin" out of control and physically fly apart. A hybrid controller fixes this by automatically diverting that excess power into the dump load resistor, which burns it off safely as heat and acts as an electronic brake to slow the turbine down.

  • No,that is the main benefit of the vertical design. Traditional horizontal "propeller" turbines create a high-pitched, annoying "chopping" noise. Our ST Tulip and Flower series utilise advanced omnidirectional maglev-style bearings, making them virtually silent and completely vibration-free, all you will hear is the wind. They are perfect for suburban blocks, tight caravan parks, and areas close to neighbours.

  • Yes.These turbines have an incredibly low startup wind speed of just 2.0 m/s, meaning the blades will begin rotating in a very gentle breeze. However, please note that physical power generation only starts accumulating once wind speeds consistently clear 4 to 5 m/s.

  • You should connect the wind turbine to a battery bank first, via a dedicated charge controller, rather than directly to an inverter. Connecting a wind turbine directly to a standard inverter will damage the equipment or cause the system to fail.

    🔋 The Correct Wiring SequenceTo safely capture and use the power, your setup must follow this exact order:

    1. Wind Turbine: Generates wild, fluctuating 3-phase AC power as wind speeds change.
    2. Hybrid/Wind Charge Controller: Converts the unstable AC power into steady DC power. It also protects the turbine from over-speeding by applying an electronic brake during high winds.
    3. Battery Bank (12V/24V/48V): Acts as a buffer to store the energy. It absorbs sudden power spikes from wind gusts and provides a steady source of energy.
    4. Off-Grid Inverter: Connects to the battery, converting the stored DC battery power into standard AC power for your household appliances.

    ⚠️ Why You Cannot Skip the Battery

    • Unstable Voltage: Wind speeds change second by second. Without a battery to absorb and smooth out these massive fluctuations, a direct-connect inverter would constantly turn off and error out.
    • Turbine Destruction: When a battery is full or disconnected, a wind turbine loses its "load" (resistance). Without that resistance, the blades can spin out of control in high winds and physically destroy the unit. The charge controller uses the battery connection to safely dump excess power and slow the turbine down.
  • Wiring & Installation Requirement:This wind turbine generates 3-phase AC power andcannotbe connected directly to a battery, solar controller, or home inverter. To operate safely, it must run through a dedicatedWind/Solar Hybrid MPPT Controller with an integrated Dump Load Resistor. The dump load prevents the turbine from over-speeding and destroying itself in high winds once your batteries are fully charged.

  • It is almost always caused by one of three common installation errors. Check these variables in order: Checking the Multi-Meter Setting (Most Common Mistake)

    • The Issue: The customer is likely measuring the three wires coming out of the turbine using a DC voltage setting on their multimeter.
    • The Reality: Wind turbines generate 3-Phase AC power directly from the stator.
    • The Fix: Instruct them to switch their multi-meter to AC Voltage (V~). Testing the wires under a DC setting will provide a false, completely inaccurate reading near zero.

    2. The Turbine is Stalling Due to Incorrect Wiring

    • The Issue: The turbine blades are spinning heavily but turning very slowly or locking up because of an electrical short.
    • The Reality: If any of the three AC output wires are accidentally touching each other, or if the controller's internal braking diodes have short-circuited, it creates a magnetic brake. This bogs down the turbine, physically stopping it from spinning fast enough to build voltage.
    • The Fix: Have them completely disconnect the turbine from the controller. If the turbine suddenly unbogs and spins much faster when disconnected, the problem is a short circuit in the wiring or a faulty controller.

    3. Voltage Drop Caused by Thin Cables

    • The Issue: The customer ran thin wiring over a long distance from the tower down to the battery shed.
    • The Reality: If they used standard thin solar cables or thin automotive wire over a long distance (e.g., 20+ metres), the natural resistance of the copper wire will choke out the electricity. The energy is lost as heat inside the wire before it ever reaches the meter.
    • The Fix: Ensure they are using heavy-duty, minimum 8 AWG or 6 AWG thick cable lines between the mast and the controller house
  • Wind turbines are rated byCumulative Daily Capacity, not instantaneous hourly peak output. Because wind speeds fluctuate constantly second-by-second, a 1200W turbine is designed to yield up to 1200W of total poweraccumulated over a 24-hour periodin optimal conditions (averaging roughly 50W per hour). This constant, steady trickle is exactly what makes vertical turbines perfect for maintaining batteries overnight when solar panels are offline.

  • Not necessarily — this is one of the most common questions we get, and it's rarely a faulty unit. It's usually a quick settings check, or (on a first-time install) how the wiring and start-up sequence were done. See our full Wind Turbine 0W Troubleshooting & Installation Guide for the complete walkthrough, or contact us and we'll help you sort it out.
  • Short Answer Wire your bus bar and breakers before and after the controller, then power up in the right order — battery first, then solar, then wind. Getting this sequence right prevents almost all wiring issues, including the common "spinning but 0W" problem. Answer (rich text field, with the link placeholder): Correct installation comes down to isolation and the right sequence: Fit a breaker before the controller (turbine/solar side) and after it (battery side), landing on a DC bus bar Keep the turbine-to-controller cable run to 2–10 metres to limit voltage drop Power up in this order: battery breaker first, then solar, then wind turbine last See our full How to Install & Start Up guide for the complete step-by-step walkthrough and wiring diagram.

Crimper Cable Cutter Wire Stripper 0.2-6mm²

Regular price $47.36 AUD
Model & colour

Tracking

Keep an eye on your gear.

Simply enter the tracking number sent to your email to see exactly where your package is and when it is estimated to arrive.

Note: It may take 24-48 hours for tracking information to update after your order has been dispatched.

Track My Order

Delivery and Shipping

At Bushline, we believe getting your gear should be easy. That is why we offer Free Standard Shipping to every customer in Australia and New Zealand. No minimum spend, no surcharges.

How Long It Takes

We quote these times from the day you place your order, not from the day we dispatch it. That is the number that actually matters to you, and quoting it any other way just moves the goalposts.

  • Most gear: 10 to 14 days from the day you order. Allow up to 3 weeks.
  • New Zealand: Same as above. NZ orders run to the same timeframe as Australian ones.
  • Large wind turbines: Allow up to 5 weeks. These are heavy, oversized units and they travel on slower freight than everything else.
  • Regional & remote areas: Please allow extra time on top of the above.

Dispatch & Tracking

  • Pick & Pack: We aim to dispatch within one business day (Monday to Friday). Most orders go out within two.
  • Weekends: Orders placed on weekends or public holidays are processed the next business day.
  • Tracking: You will get a Shipping Confirmation email with your tracking number as soon as your order ships.

If Your Order Is Running Late

Ring 0400 333 898 or email Support@BushLine.com.au and we will chase the tracking ourselves rather than sending you off to do it. You will get a straight answer on where it is, including if it has not moved.

Need A Large Turbine Sooner?

Expedited freight is available on the big units at extra cost, which brings delivery down to roughly a fortnight. It is quoted per order because it depends on the size of the unit and where it is going. Get in touch before you order and we will price it for you.

D1, D2, D3 — a model code, not a colour.

Making up your own cable ends off-grid means three separate jobs on every run: cut the cable square, strip the insulation without nicking the strands, then crimp the terminal on tight enough that it never heats up. Doing that with side cutters and a pair of pliers is how you end up with a joint that reads fine on a multimeter and gets warm under load six months later.

This is a 205mm combination tool that does all three. The cutter head is Cr12MoV at HRC55-60, the plier body is A3 heat-treated steel, the head is zinc alloy and the handle is PP+TPR. There is an adjusting screw on the stripping jaw so you can dial the blade bite up for tough insulation or back it off for thin conductors — turn it clockwise for more bite, counter-clockwise for less.

Be clear on what it is: it is a hand tool for small and mid-size conductors, 0.2-6mm². It is not a hydraulic lug crimper. If you are terminating 16mm² or heavier battery cable onto copper SC lugs, this tool will not reach that size — you want a proper lug crimper for those.

What It Solves
  • Van and camper wiring: running 12V lighting, fridge and USB circuits in 1-2.5mm² where every joint has to survive corrugations.
  • Farm shed and pump work: re-terminating control and sensor wiring in the shed without dragging the full toolbox out.
  • Solar and turbine sensor runs: the thin stuff — anemometer leads, shunt sense wires, temperature probes — that a big crimper mangles.
  • Trailer and boat repairs: a broken tail-light lead or bilge pump feed fixed properly at the ramp instead of taped up.
  • One tool in the glovebox: cut, strip and crimp in a single 205mm tool when you cannot carry three.
Key Features
  • Stripping range: 0.2-6mm² (24-10AWG), supplier-stated.
  • Insulated terminal crimping: 0.5-6mm² (22-10AWG), supplier-stated.
  • Non-insulated terminal dies: three separate supplier-stated ranges — 4-6mm² (12-10AWG), 1.5-2.5mm² (16-14AWG) and 0.5-1mm² (22-18AWG).
  • Adjustable blade tension: a screw sets how hard the stripping blades bite — clockwise for more, counter-clockwise for less.
  • Cutter head: Cr12MoV tool steel, hardness HRC55-60, wire-cut finished.
  • Plier body: A3 steel, heat treated, with a zinc alloy head.
  • Handle: PP with a TPR over-mould, so it is not bare plastic in the palm.
  • Overall length: 205mm — fits a tool pouch, not a drawer.
  • Nine listed options: the D1, D2 and D3 prefix is the supplier's model code and the colour follows it. The supplier gives one spec sheet for all nine.
Where This Fits

Wiring an off-grid system means making up your own cable ends. This is one of the tools for that job — here's the rest of the picture:

Off-grid wiring layout — vertical axis wind turbine and solar panel into a hybrid MPPT controller, with dump load, main battery circuit breaker, DC bus bar, 12V 24V 48V battery bank and inverter

  • Wind turbines: vertical axis turbines from 1kW to 20kW — quiet enough to put near the house, and they charge overnight when your solar can't.
  • Hybrid MPPT controllers: you can't wire a turbine straight to a battery. The controller rectifies the output, manages the charge, and brakes the turbine when the bank is full.
  • The rest of the electrical range: bus bars, breakers, isolators, cable, lugs and Anderson plugs.

Cable sizing depends on your run length, voltage and current, and a bad crimp is the connection that heats up later — check the sizing against your own run or ask your sparky before you make up anything you can't undo.

Q & A

What's the difference between D1, D2 and D3?

The supplier does not say. D1, D2 and D3 are its model codes and the colour name follows the code — "D2 Blue" is model D2 in blue. The one spec block supplied covers all nine options: same 205mm length, same head and handle materials, same stripping and crimping ranges. We have asked for the difference and will put it here when we have it. If the distinction matters to your job, email us before you order rather than guessing.

Will it crimp 16mm² battery cable onto a lug?

No. The largest supplier-stated crimp is 6mm² (10AWG) on insulated terminals. Heavy battery cable and copper SC lugs need a hydraulic or long-handle lug crimper.

Why are there four different crimping ranges listed?

Because there are separate dies in the jaw. The supplier lists insulated terminals at 0.5-6mm² (22-10AWG), and three non-insulated ranges at 4-6mm² (12-10AWG), 1.5-2.5mm² (16-14AWG) and 0.5-1mm² (22-18AWG). The supplier does not label which nest on the tool corresponds to which range, so match your terminal to the die by trial on an offcut before you commit to a real joint.

It's cutting into the strands when I strip — can I fix that?

Yes. That is what the adjusting screw is for. Turn it counter-clockwise to reduce the blade bite, a little at a time, and test on an offcut. If it is slipping and not stripping at all, go clockwise instead.

Does it come with terminals?

Not specified by supplier. Assume tool only and order terminals separately.

Is it certified to any standard?

No standard is stated by the supplier — no VDE, CE or AS/NZS claim. It is a general-purpose hand tool. If your work needs a certified insulated tool, this is not it.

Specs

Specification Detail
Overall length 205mm
Stripping range 0.2-6mm² (24-10AWG)
Crimping — insulated terminals 0.5-6mm² (22-10AWG)
Crimping — non-insulated terminals Three supplier-stated ranges: 4-6mm² (12-10AWG), 1.5-2.5mm² (16-14AWG), 0.5-1mm² (22-18AWG)
Cutting capacity Not specified by supplier
Blade tension adjustment Screw adjustable — clockwise increases bite, counter-clockwise reduces it
Cutter head material Cr12MoV tool steel, wire-cut
Cutter head hardness HRC55-60
Head material Zinc alloy
Plier body A3 steel, heat treated
Handle material PP + TPR
Model and colour options Nine: D1 yellow, D1 red, D2 blue, D2 yellow, D2 orange-red, D2 green, D2 grey, D3 dark green, D3 green and yellow
Difference between D1, D2 and D3 Not specified by supplier
Insulated / VDE rated Not specified by supplier — do not treat as a live-work tool
Weight Not specified by supplier
Certification Not specified by supplier
Country of origin Not specified by supplier
In the box Not specified by supplier — assume tool only

Watch Me

No video for this one yet. If you want to see it working before you buy, email help@bushline.com.au and we'll get footage up.

Payment & Security

Payment Methods

  • American Express
  • Apple Pay
  • Google Pay
  • Mastercard
  • PayPal
  • Visa

Your payment information is processed securely.

We do not store credit card details or have access to your credit card information.

Wind Turbine FAQs

  • Summary Checklist for Your Choice

    Choose the SR or ST-1200W if you want portability, low noise, and minimal investment for camping or caravans.

    Choose the ST-2000, ST-3000, or ST-5000 if you have a stationary house/cabin and want to supplement solar panels at night.

    Choose the ST-10kW or 20kW if you have heavy agricultural power needs, acreage, and a budget for proper mast engineering.

    The vertical axis wind turbines listed on the BushLine Outdoor Equipment catalog are categorized by physical design shapes, which dictate their ideal applications.

  • No.Wind turbines generate "wild" 3-phase AC power that changes voltage constantly with the wind speed. Connecting it directly to a battery or a standard solar inverter will instantly destroy your equipment. Youmustwire the turbine into a dedicatedWind/Solar Hybrid MPPT Controller with an integrated Dump Load Resistor. The controller converts the power to stable DC to charge your batteries safely.

  • You must match the turbine and its hybrid controller to the exact voltage of your existing battery bank:

    • 12V: Best for compact mobile setups like caravans, 4WDs, and camper trailers.
    • 24V: Great for medium-sized setups like off-grid sheds, cabins, and motorhomes.
    • 48V: The gold standard for full off-grid home systems. Higher voltage means less energy loss through your wires and allows you to use thinner, safer cables.
  • When your battery bank becomes 100% fully charged, it stops accepting power. If a heavy wind storm hits at night when your batteries are full, a turbine with nowhere to send its power will "free-spin" out of control and physically fly apart. A hybrid controller fixes this by automatically diverting that excess power into the dump load resistor, which burns it off safely as heat and acts as an electronic brake to slow the turbine down.

  • No,that is the main benefit of the vertical design. Traditional horizontal "propeller" turbines create a high-pitched, annoying "chopping" noise. Our ST Tulip and Flower series utilise advanced omnidirectional maglev-style bearings, making them virtually silent and completely vibration-free, all you will hear is the wind. They are perfect for suburban blocks, tight caravan parks, and areas close to neighbours.

  • Yes.These turbines have an incredibly low startup wind speed of just 2.0 m/s, meaning the blades will begin rotating in a very gentle breeze. However, please note that physical power generation only starts accumulating once wind speeds consistently clear 4 to 5 m/s.

  • You should connect the wind turbine to a battery bank first, via a dedicated charge controller, rather than directly to an inverter. Connecting a wind turbine directly to a standard inverter will damage the equipment or cause the system to fail.

    🔋 The Correct Wiring SequenceTo safely capture and use the power, your setup must follow this exact order:

    1. Wind Turbine: Generates wild, fluctuating 3-phase AC power as wind speeds change.
    2. Hybrid/Wind Charge Controller: Converts the unstable AC power into steady DC power. It also protects the turbine from over-speeding by applying an electronic brake during high winds.
    3. Battery Bank (12V/24V/48V): Acts as a buffer to store the energy. It absorbs sudden power spikes from wind gusts and provides a steady source of energy.
    4. Off-Grid Inverter: Connects to the battery, converting the stored DC battery power into standard AC power for your household appliances.

    ⚠️ Why You Cannot Skip the Battery

    • Unstable Voltage: Wind speeds change second by second. Without a battery to absorb and smooth out these massive fluctuations, a direct-connect inverter would constantly turn off and error out.
    • Turbine Destruction: When a battery is full or disconnected, a wind turbine loses its "load" (resistance). Without that resistance, the blades can spin out of control in high winds and physically destroy the unit. The charge controller uses the battery connection to safely dump excess power and slow the turbine down.
  • Wiring & Installation Requirement:This wind turbine generates 3-phase AC power andcannotbe connected directly to a battery, solar controller, or home inverter. To operate safely, it must run through a dedicatedWind/Solar Hybrid MPPT Controller with an integrated Dump Load Resistor. The dump load prevents the turbine from over-speeding and destroying itself in high winds once your batteries are fully charged.

  • It is almost always caused by one of three common installation errors. Check these variables in order: Checking the Multi-Meter Setting (Most Common Mistake)

    • The Issue: The customer is likely measuring the three wires coming out of the turbine using a DC voltage setting on their multimeter.
    • The Reality: Wind turbines generate 3-Phase AC power directly from the stator.
    • The Fix: Instruct them to switch their multi-meter to AC Voltage (V~). Testing the wires under a DC setting will provide a false, completely inaccurate reading near zero.

    2. The Turbine is Stalling Due to Incorrect Wiring

    • The Issue: The turbine blades are spinning heavily but turning very slowly or locking up because of an electrical short.
    • The Reality: If any of the three AC output wires are accidentally touching each other, or if the controller's internal braking diodes have short-circuited, it creates a magnetic brake. This bogs down the turbine, physically stopping it from spinning fast enough to build voltage.
    • The Fix: Have them completely disconnect the turbine from the controller. If the turbine suddenly unbogs and spins much faster when disconnected, the problem is a short circuit in the wiring or a faulty controller.

    3. Voltage Drop Caused by Thin Cables

    • The Issue: The customer ran thin wiring over a long distance from the tower down to the battery shed.
    • The Reality: If they used standard thin solar cables or thin automotive wire over a long distance (e.g., 20+ metres), the natural resistance of the copper wire will choke out the electricity. The energy is lost as heat inside the wire before it ever reaches the meter.
    • The Fix: Ensure they are using heavy-duty, minimum 8 AWG or 6 AWG thick cable lines between the mast and the controller house
  • Wind turbines are rated byCumulative Daily Capacity, not instantaneous hourly peak output. Because wind speeds fluctuate constantly second-by-second, a 1200W turbine is designed to yield up to 1200W of total poweraccumulated over a 24-hour periodin optimal conditions (averaging roughly 50W per hour). This constant, steady trickle is exactly what makes vertical turbines perfect for maintaining batteries overnight when solar panels are offline.

  • Not necessarily — this is one of the most common questions we get, and it's rarely a faulty unit. It's usually a quick settings check, or (on a first-time install) how the wiring and start-up sequence were done. See our full Wind Turbine 0W Troubleshooting & Installation Guide for the complete walkthrough, or contact us and we'll help you sort it out.
  • Short Answer Wire your bus bar and breakers before and after the controller, then power up in the right order — battery first, then solar, then wind. Getting this sequence right prevents almost all wiring issues, including the common "spinning but 0W" problem. Answer (rich text field, with the link placeholder): Correct installation comes down to isolation and the right sequence: Fit a breaker before the controller (turbine/solar side) and after it (battery side), landing on a DC bus bar Keep the turbine-to-controller cable run to 2–10 metres to limit voltage drop Power up in this order: battery breaker first, then solar, then wind turbine last See our full How to Install & Start Up guide for the complete step-by-step walkthrough and wiring diagram.