Wind Turbine FAQs

    • Start with two questions: how much wind your site actually gets, and how much room you have.
    • Vertical turbines (the X-300, H1000 and H2000) start turning at 2 to 2.5 m/s and take wind from any direction, so they keep working where the wind swirls and shifts — around buildings, trees and rooflines. They run from 300 W up to 2000 W.
    • Horizontal turbines (M-400, M-600, M-800, and the L1, L2 and G series) want cleaner, steadier wind and a clear run at it. In clean, steady wind a horizontal of the same rating is usually the better harvester, and they scale further — 400 W up to 5000 W.
    • Match the turbine to your battery bank, not to the biggest number. 12 V suits a camper, 4WD or tinnie; 24 V a van, cabin or boat; 48 V a shed or remote block.
    1. The largest models run at mains voltage, and the L2-3000, G-3000 and G-5000 are ground-mount only — they need a 10–15 m mast and are not rooftop units.
    2. Rated power is measured at 10–14 m/s, depending on the model. What you get at your place depends on your wind, your mast height and the season — not on a number on our website.
    1. No. Wind turbines generate "wild" 3-phase AC power that changes voltage constantly with the wind speed.
    2. Connecting it directly to a battery or a standard solar inverter will destroy your equipment.
    • You must wire the turbine into a dedicated wind charge controller (pure-wind or wind-solar hybrid) with a dump-load resistor.
    • The controller converts the power to stable DC to charge your batteries safely.
  • Match the turbine and its controller to the voltage of your existing battery bank:

    • 12 V: compact mobile setups — caravans, 4WDs and camper trailers.
    • 24 V: medium setups — off-grid sheds, cabins and motorhomes.
    • 48 V: most of this range, and the sensible choice for a full off-grid system. Higher voltage means less current in the cable, so less loss over a long run and lighter cable.
    • When your battery bank is fully charged it stops accepting power.
    1. If a storm hits at night with the batteries full, a turbine with nowhere to send its power will free-spin out of control and can physically fly apart.
    • The controller prevents that by diverting the excess into the dump load resistor, which burns it off safely as heat and acts as an electronic brake to slow the turbine down.
    • Yes, you need one.
    • Usually quieter, but not silent — no turbine is.
    • Why a Horizontal is Louder: its blade tips travel several times faster than the wind, and blade noise climbs steeply with tip speed. The whoosh rises and falls as each blade comes round — a rhythmic swish that carries through wind noise more than a steady hiss does.
    • Why a Vertical is Usually Quieter: its blades turn more slowly, so there is less of that whoosh.
    1. What we won't Tell you: that it's silent. Every turbine gets louder as the wind picks up. The wind often covers much of it in a strong blow, but a close neighbour can still hear one in light to moderate wind.
    2. The manufacturer publishes no noise figure for the turbines themselves (the "65 dB or less" on some Specs tabs is the controller's), so we don't quote one.
    • On a building, use vibration isolators — a turbine bolted to a structure carries its sound into the rooms — and check your council's rules on noise, height and placement before you order a mast.
    • It will turn, but turning is not charging. The blades start turning at 2 to 2.5 m/s (about 7 to 9 km/h) — a light breeze.
    • Charging starts at the cut-in speed: 3 m/s (about 11 km/h) on every model except the X-300, which starts and charges from 2 m/s. Output then climbs steeply with wind speed.
    1. The rated figure is measured much higher — 10 to 14 m/s depending on the model, a 36 to 50 km/h wind, not a normal afternoon. Each product page's spec table gives that model's own numbers.
    • A gentle breeze keeps the turbine ticking over; it takes real wind to push real power into your batteries. Every horizontal model has its measured power curve published on its product page — work from that, not from the number in the product name.
    • No — small turbines are built to spin fast. The smaller the rotor, the faster it has to turn to keep its blade tips up with the wind: the M-400's 1.35 m rotor runs at about 800 rpm, the M-600 and M-800 at about 500, the big G-series at 300.
    • In the manufacturer's words, the high rpm is a design necessity, not a defect. A slower generator would need a bigger stator and more magnets and copper — heavier and dearer.
    • They start turning at 2 to 2.5 m/s and make power right across the wind range — just less when the wind is light. What you get depends on your site and how high you mount it.
    • Yes — connect the turbine to a battery bank first, through a dedicated charge controller.
    1. Never straight to an inverter. Connecting a wind turbine directly to a standard inverter will damage the equipment or cause the system to fail.

    The Correct Order:

    • 1. Wind Turbine — generates wild, fluctuating 3-phase AC as the wind changes.
    • 2. Hybrid or Wind Charge Controller — converts it to steady DC, and protects the turbine from over-speeding with an electronic brake.
    • 3. Battery Bank (12 V, 24 V or 48 V) — absorbs the gusts and provides a steady source of energy.
    • 4. Off-Grid Inverter — connects to the battery, converting stored DC into AC for your appliances.

    Why you Cannot Skip the Battery:

    1. Unstable Voltage: wind changes second by second. Without a battery to smooth it out, a direct-connected inverter would constantly cut out.
    2. Turbine Damage: when a battery is full or disconnected, the turbine loses its load. Without that resistance the blades can spin out of control in high wind and destroy the unit. The controller uses the battery connection to dump excess power and slow it down.
    1. This turbine generates 3-phase AC power and cannot be connected directly to a battery, a solar controller or a home inverter.
    • It must run through a dedicated wind charge controller (pure-wind or wind-solar hybrid) with a dump-load resistor. The dump load stops the turbine over-speeding and destroying itself in high winds once your batteries are full.
    • Installation and commissioning must be carried out by a suitably qualified and licensed electrician.
    • Cable, breakers, isolators and all protective devices are selected to suit your site and are the electrician's call, not ours.
  • It is almost always one of three installation issues. Check them in order.

    Quick Checks — Tick as You Go

    • Is the Meter Set to AC Volts (V~)?
    • Does it Spin Freely Once Disconnected from the Controller?
    • Is the Cable from the Mast Heavy Enough for the Run?

    1. The Multimeter is Set to DC — The Most Common Mistake.

    1. Measuring the three turbine wires with the meter set to DC volts gives a false reading near zero.
    • Wind turbines generate 3-phase AC directly from the stator. Switch the meter to AC volts (V~).

    2. The Turbine is Stalling Because of a Short.

    1. The blades turn heavily and slowly, or lock up: if any of the three AC output wires touch each other, or the controller's braking diodes have short-circuited, it acts as a magnetic brake — the turbine can never spin fast enough to build voltage.
    • Disconnect the turbine from the controller. If it frees up and spins much faster, the problem is a short in the wiring or a faulty controller.

    3. Voltage Drop from Thin Cable.

    1. Thin solar or automotive cable over 20 metres or more loses the power as heat before it reaches the controller.
    • Use heavy cable between the mast and the controller on long runs — minimum 8 AWG, ideally 6 AWG. Final sizing is your electrician's call.
    • The number in the name is a peak rating, not a promise.
    • A turbine's rated output is measured at a specific wind speed — 10 to 14 m/s depending on the model, which is about 36 to 50 km/h — and most sites see far less than that most of the time.
    • Your display shows what the wind is delivering right now, so it will sit well below the rated figure and move second by second as the wind changes. That is physics, not a fault.
    • As an example, the L2-2500 is rated 2,500 W at 11 m/s. On a decent steady coastal breeze of 7 m/s the manufacturer's own curve gives about 813 W. That is why we publish the full power curve on every horizontal turbine's product page.
    • Where these machines earn their keep is time: they keep charging through the night and through the weather that shuts solar down.
    1. If the display shows 0 W while the blades are spinning, that is a different problem — see the 0 W question.
    • Not necessarily — this is one of the most common questions we get, and it is rarely a faulty unit.
    • It is usually a quick settings check, or (on a first-time install) how the wiring and start-up sequence were done.
    • See our full Wind Turbine 0W Troubleshooting Guide for the complete walkthrough, or the Set-Up Guide — or contact us and we will help you sort it out.
    • Wire your bus bar and breakers before and after the controller, then power up in the right order. Getting the sequence right prevents almost all wiring issues, including the common "spinning but 0 W" problem.
    • Fit a breaker before the controller (turbine/solar side) and after it (battery side), landing on a DC bus bar.
    • Keep the turbine-to-controller cable run to 2–10 metres to limit voltage drop.
    • Power up in this order: battery breaker first, then solar, then wind turbine last.
    • See our full How to Install & Start Up guide for the complete step-by-step walkthrough and wiring diagram.

Pure Sine Wave Inverter 3000W 4000W 5000W Peak - 12V or 24V

Regular price $499.95 AUD
Watts
Input Voltage

Delivering Outside Australia or New Zealand? Delivery is free. Import duty, customs charges and any tax on arrival are set by your country and are payable by you — we can’t collect them for you.

Tracking

Keep an Eye on your Gear

Simply enter the tracking number sent to your email to see exactly where your package is and when it is estimated to arrive.

Note: It may take 24-48 hours for tracking information to update after your order has been dispatched.

Track my Order

The Number on the Lid is Not the Number it Runs

You buy the 5000W, wire it to the bank, plug in a 2400W kettle and the thing shuts down. Nothing is broken. 5000W is the surge figure. The continuous rating is printed on the same label, on the line directly below it, and it says 2500W.

That is the whole story on this inverter and it is worth getting straight before you spend anything. RDDSPON print both numbers themselves: the 3000W runs 1500W continuous, the 4000W runs 2000W, the 5000W runs 2500W. Halve the model name and you have the figure to size your gear against.

Get it wrong and the shutdown does not happen in the driveway while you are watching. It happens at two in the morning with a full chest freezer on it, or halfway through a cut with the grinder winding down in your hand. Size off the continuous figure and the thing just works.

What it Does
  • Turns a Battery into Mains: takes 12V or 24V DC from your bank and puts out 220V AC through two universal sockets.
  • Runs 1500W to 2500W All Day: continuous output depends on the model you pick — 1500W, 2000W or 2500W.
  • Handles the Start-Up Spike: the 3000W, 4000W and 5000W headline figures are the surge the unit will take when a motor or compressor kicks in.
  • Gives you a Clean Waveform: the label says pure sine wave and prints the waveform beside it, which is what fridges, tools with electronics and chargers want to see.
  • Tells you What is Happening: the multifunction LCD reads DC input volts, AC output volts, watts drawn and frequency, all on one screen.
  • Sits in a Camp or a Shed: 1.8kg to 2.65kg with mounting flanges each end, so it bolts down rather than sliding about the tray.
Key Features
  • Continuous Ratings on the Label: 1500W, 2000W and 2500W, printed by the manufacturer under the model name rather than buried in a datasheet.
  • Two Universal Outlets: the socket pattern takes Australian and New Zealand angled pins, plus round and flat pin plugs.
  • Screw Post DC Terminals: a red positive and a black negative post, so you land a proper lug rather than a spring clip.
  • Leads & Clamps Included: DC leads and two battery post clamps come in the box. The 5000W ships with two pairs of leads, the 3000W and 4000W with one.
  • Fan Cooling, Sized to Model: one fan on the 3000W, two 12V fans on the 4000W and 5000W, drawing through a finned aluminium case.
  • Power & Fault Lights: the 4000W and 5000W front panels carry a green power lamp and a red fault lamp beside the rocker switch.
  • Built for One Bank Voltage: each unit is made as a 12V or a 24V inverter. It is a build option, not a switch on the case, so you choose it at checkout.
  • Compact for the Output: the largest of the three is 314mm long and weighs 2.65kg.
Where it Stops
  • It is Not a 5kW Inverter: the biggest one runs 2500W continuously. If you need 5000W all day, this is the wrong unit and no wiring trick changes that.
  • A 24V Unit on a 12V Bank is a Brick: and a 12V unit on 24V is worse. Pick the input voltage that matches the bank you already have.
  • It does Not Charge Anything: an inverter only takes power out of a battery. Something else has to put it back in.
  • Not for Fixed Wiring: do not connect it to the power points of a house, shed or caravan. Wiring an inverter into fixed circuits is licensed electrical work in Australia and New Zealand. Plug appliances straight into the sockets on the front.
  • No Australian Compliance Mark: the label carries a CE mark and recycling marks. There is no RCM mark on it, which is the Australian and New Zealand one, and we have not sighted a test certificate for any mark.
  • Keep it Dry & Clear: it is a vented, fan-cooled aluminium case with open fins. It is not sealed against water or dust, and blocking the fans will cook it.
What Else you'll Need

An inverter is half a system. It empties the bank; it never fills it. This is the gear that goes around it, and why each piece earns its place:

Q & A

So is the 5000W a 5000W Inverter or a 2500W One?

A 2500W one, with 5000W of surge headroom. The manufacturer prints both figures on the case: "INVERTER 5000W" in large type, and "Continuous Output Power: 2500W" on the line below it. Size every calculation you do off 2500W. The 5000W number only matters for the half-second when a compressor or a power tool starts up. The supplier does not state how long the unit will hold the surge figure, so we cannot tell you either.

Will the Biggest One Run a 2400W Kettle?

It is right on the line, and we would not build a camp around it. 2400W against a 2500W continuous rating leaves you 100W of margin before the inverter has had a hot day, a long cable or a bank sitting at the low end of its voltage. A kettle is one of the harshest things you can ask an inverter to do because it pulls its full load the entire time it is on.

Can I Run the 24V Version Off a 12V Battery?

No. Each unit is built for one bank voltage and it is not switchable — the label has a tick box for 12V or 24V and the factory ticks one. A 24V inverter on a 12V bank will not work, and a 12V inverter on a 24V bank is a good way to destroy it. Check what your bank actually is before you choose the variant, because it is the one decision on this page you cannot undo later.

Is the Output 220V or 240V?

The supplier's specification panel says 220V nominal, and so does the label. Australian and New Zealand mains sits at 230V nominal, and most gear sold here is marked 220–240V on its rating plate, which covers it. If you are running something with a narrow input range, read its rating plate and check 220V falls inside it. The displays in the manufacturer's own photographs read between 223V and 239V under load.

What Size Cable and Fuse does it Need?

Bigger than most people expect, and we are not going to guess it for you. The supplier does not publish the DC input current at full load, and that figure is what decides your cable size and your fuse rating. Working a 2500W load out of a 12V bank pulls hundreds of amps on the DC side, which is a different class of wiring from anything on the AC side of the unit. Size the cable and the fuse from the real measured draw, keep the run short, and if you are not confident doing that, have an auto electrician do it.

Can I Wire it into the Caravan's Power Points?

No. Plug your appliances directly into the two sockets on the front. Connecting an inverter to the fixed wiring of a van, shed or house is licensed electrical work here, and back-feeding a circuit is how people get hurt.

Is it Really a Pure Sine Wave Unit?

The manufacturer says so and prints a sine waveform on the case beside the words "Pure Sine Wave". We have not put one on an oscilloscope ourselves, so that is the manufacturer's statement rather than our measurement. It matters because a modified sine wave sold as pure sine will make induction motors run hot and can upset sensitive chargers and electronics.

Specs

Specifications Details
Brand RDDSPON
Models 3000W, 4000W, 5000W (These are the Peak Figures)
Continuous Output Power 1500W / 2000W / 2500W — printed on the product label
Peak Output Power 3000W / 4000W / 5000W
Peak Duration Not Specified by Supplier
Output Waveform Pure Sine Wave (Stated & Illustrated on the Label)
DC Input Voltage 12V or 24V — built as one or the other, not switchable
DC Input Voltage Range Not Specified by Supplier
DC Input Current at Full Load Not Specified by Supplier
AC Output Voltage 220V Nominal
Output Frequency Label lists 50Hz and 60Hz with neither box ticked. Every display in the supplier's photographs reads 50Hz
AC Outlets 2 × Universal Multi-Fit Sockets
Display Multifunction LCD — DC Volts, AC Volts, Watts, Frequency
Indicators Green power lamp and red fault lamp (shown on the 4000W and 5000W panels)
Switch Rocker Switch Marked ON / OFF
Cooling 1 fan (3000W); 2 × 12V Fans (4000W & 5000W)
Conversion Efficiency Not Specified by Supplier
No-Load Current Draw Not Specified by Supplier
Low-Voltage Cutoff & Restart Not Specified by Supplier
Protection Functions Not specified by supplier — a fault lamp is fitted, but the supplier does not state what triggers it
DC Terminals Red positive and black negative screw posts. Stud size not specified by supplier
Case Finned Aluminium with Mounting Flanges Each End
Dimensions (Spec Panel) 3000W 292 × 130 × 70mm / 4000W 268 × 150 × 72mm / 5000W 314 × 150 × 72mm
Overall Length (Drawing) 292mm / 282mm / 330mm — the supplier's dimensioned drawing is 14–16mm longer than its own table on the two larger models. Allow the larger figure when you plan a mounting space
Net Weight 1.8kg / 2.2kg / 2.65kg
Supplied with DC leads and 2 battery post clamps. Two pairs of leads on the 5000W, one pair on the 3000W and 4000W
Markings CE and recycling marks on the label. No RCM mark. No test certificate sighted

Watch Me

No Video on This One Yet

We would rather put up nothing than a supplier's stock reel of a different inverter. When we get one on a bench with a bank and a load on it, it goes here.

In the meantime, the two things worth reading before it arrives:

  • Sizing the Bank Behind it: an inverter is only as good as what is feeding it. The charge controller range covers what puts the charge back in.
  • Turbine Spinning but Showing 0W: the most common call we get on an off-grid system, and it is almost never a dud unit. The 0W troubleshooting guide walks through it.

Still stuck? Ring 0400 333 898. A real person picks up, and if we do not know the answer we will say so.

Free Standard Delivery. Allow 5 to 10 working days from the day you order. Allow 1–2 days for fulfilment. Regional and remote addresses can take longer.

Payment & Security

Payment Methods

  • American Express
  • Apple Pay
  • Bancontact
  • BLIK
  • Google Pay
  • Mastercard
  • MB WAY
  • PayPal
  • Satispay
  • Visa

Your payment information is processed securely.

We do not store credit card details or have access to your credit card information.

Wind Turbine FAQs

    • Start with two questions: how much wind your site actually gets, and how much room you have.
    • Vertical turbines (the X-300, H1000 and H2000) start turning at 2 to 2.5 m/s and take wind from any direction, so they keep working where the wind swirls and shifts — around buildings, trees and rooflines. They run from 300 W up to 2000 W.
    • Horizontal turbines (M-400, M-600, M-800, and the L1, L2 and G series) want cleaner, steadier wind and a clear run at it. In clean, steady wind a horizontal of the same rating is usually the better harvester, and they scale further — 400 W up to 5000 W.
    • Match the turbine to your battery bank, not to the biggest number. 12 V suits a camper, 4WD or tinnie; 24 V a van, cabin or boat; 48 V a shed or remote block.
    1. The largest models run at mains voltage, and the L2-3000, G-3000 and G-5000 are ground-mount only — they need a 10–15 m mast and are not rooftop units.
    2. Rated power is measured at 10–14 m/s, depending on the model. What you get at your place depends on your wind, your mast height and the season — not on a number on our website.
    1. No. Wind turbines generate "wild" 3-phase AC power that changes voltage constantly with the wind speed.
    2. Connecting it directly to a battery or a standard solar inverter will destroy your equipment.
    • You must wire the turbine into a dedicated wind charge controller (pure-wind or wind-solar hybrid) with a dump-load resistor.
    • The controller converts the power to stable DC to charge your batteries safely.
  • Match the turbine and its controller to the voltage of your existing battery bank:

    • 12 V: compact mobile setups — caravans, 4WDs and camper trailers.
    • 24 V: medium setups — off-grid sheds, cabins and motorhomes.
    • 48 V: most of this range, and the sensible choice for a full off-grid system. Higher voltage means less current in the cable, so less loss over a long run and lighter cable.
    • When your battery bank is fully charged it stops accepting power.
    1. If a storm hits at night with the batteries full, a turbine with nowhere to send its power will free-spin out of control and can physically fly apart.
    • The controller prevents that by diverting the excess into the dump load resistor, which burns it off safely as heat and acts as an electronic brake to slow the turbine down.
    • Yes, you need one.
    • Usually quieter, but not silent — no turbine is.
    • Why a Horizontal is Louder: its blade tips travel several times faster than the wind, and blade noise climbs steeply with tip speed. The whoosh rises and falls as each blade comes round — a rhythmic swish that carries through wind noise more than a steady hiss does.
    • Why a Vertical is Usually Quieter: its blades turn more slowly, so there is less of that whoosh.
    1. What we won't Tell you: that it's silent. Every turbine gets louder as the wind picks up. The wind often covers much of it in a strong blow, but a close neighbour can still hear one in light to moderate wind.
    2. The manufacturer publishes no noise figure for the turbines themselves (the "65 dB or less" on some Specs tabs is the controller's), so we don't quote one.
    • On a building, use vibration isolators — a turbine bolted to a structure carries its sound into the rooms — and check your council's rules on noise, height and placement before you order a mast.
    • It will turn, but turning is not charging. The blades start turning at 2 to 2.5 m/s (about 7 to 9 km/h) — a light breeze.
    • Charging starts at the cut-in speed: 3 m/s (about 11 km/h) on every model except the X-300, which starts and charges from 2 m/s. Output then climbs steeply with wind speed.
    1. The rated figure is measured much higher — 10 to 14 m/s depending on the model, a 36 to 50 km/h wind, not a normal afternoon. Each product page's spec table gives that model's own numbers.
    • A gentle breeze keeps the turbine ticking over; it takes real wind to push real power into your batteries. Every horizontal model has its measured power curve published on its product page — work from that, not from the number in the product name.
    • No — small turbines are built to spin fast. The smaller the rotor, the faster it has to turn to keep its blade tips up with the wind: the M-400's 1.35 m rotor runs at about 800 rpm, the M-600 and M-800 at about 500, the big G-series at 300.
    • In the manufacturer's words, the high rpm is a design necessity, not a defect. A slower generator would need a bigger stator and more magnets and copper — heavier and dearer.
    • They start turning at 2 to 2.5 m/s and make power right across the wind range — just less when the wind is light. What you get depends on your site and how high you mount it.
    • Yes — connect the turbine to a battery bank first, through a dedicated charge controller.
    1. Never straight to an inverter. Connecting a wind turbine directly to a standard inverter will damage the equipment or cause the system to fail.

    The Correct Order:

    • 1. Wind Turbine — generates wild, fluctuating 3-phase AC as the wind changes.
    • 2. Hybrid or Wind Charge Controller — converts it to steady DC, and protects the turbine from over-speeding with an electronic brake.
    • 3. Battery Bank (12 V, 24 V or 48 V) — absorbs the gusts and provides a steady source of energy.
    • 4. Off-Grid Inverter — connects to the battery, converting stored DC into AC for your appliances.

    Why you Cannot Skip the Battery:

    1. Unstable Voltage: wind changes second by second. Without a battery to smooth it out, a direct-connected inverter would constantly cut out.
    2. Turbine Damage: when a battery is full or disconnected, the turbine loses its load. Without that resistance the blades can spin out of control in high wind and destroy the unit. The controller uses the battery connection to dump excess power and slow it down.
    1. This turbine generates 3-phase AC power and cannot be connected directly to a battery, a solar controller or a home inverter.
    • It must run through a dedicated wind charge controller (pure-wind or wind-solar hybrid) with a dump-load resistor. The dump load stops the turbine over-speeding and destroying itself in high winds once your batteries are full.
    • Installation and commissioning must be carried out by a suitably qualified and licensed electrician.
    • Cable, breakers, isolators and all protective devices are selected to suit your site and are the electrician's call, not ours.
  • It is almost always one of three installation issues. Check them in order.

    Quick Checks — Tick as You Go

    • Is the Meter Set to AC Volts (V~)?
    • Does it Spin Freely Once Disconnected from the Controller?
    • Is the Cable from the Mast Heavy Enough for the Run?

    1. The Multimeter is Set to DC — The Most Common Mistake.

    1. Measuring the three turbine wires with the meter set to DC volts gives a false reading near zero.
    • Wind turbines generate 3-phase AC directly from the stator. Switch the meter to AC volts (V~).

    2. The Turbine is Stalling Because of a Short.

    1. The blades turn heavily and slowly, or lock up: if any of the three AC output wires touch each other, or the controller's braking diodes have short-circuited, it acts as a magnetic brake — the turbine can never spin fast enough to build voltage.
    • Disconnect the turbine from the controller. If it frees up and spins much faster, the problem is a short in the wiring or a faulty controller.

    3. Voltage Drop from Thin Cable.

    1. Thin solar or automotive cable over 20 metres or more loses the power as heat before it reaches the controller.
    • Use heavy cable between the mast and the controller on long runs — minimum 8 AWG, ideally 6 AWG. Final sizing is your electrician's call.
    • The number in the name is a peak rating, not a promise.
    • A turbine's rated output is measured at a specific wind speed — 10 to 14 m/s depending on the model, which is about 36 to 50 km/h — and most sites see far less than that most of the time.
    • Your display shows what the wind is delivering right now, so it will sit well below the rated figure and move second by second as the wind changes. That is physics, not a fault.
    • As an example, the L2-2500 is rated 2,500 W at 11 m/s. On a decent steady coastal breeze of 7 m/s the manufacturer's own curve gives about 813 W. That is why we publish the full power curve on every horizontal turbine's product page.
    • Where these machines earn their keep is time: they keep charging through the night and through the weather that shuts solar down.
    1. If the display shows 0 W while the blades are spinning, that is a different problem — see the 0 W question.
    • Not necessarily — this is one of the most common questions we get, and it is rarely a faulty unit.
    • It is usually a quick settings check, or (on a first-time install) how the wiring and start-up sequence were done.
    • See our full Wind Turbine 0W Troubleshooting Guide for the complete walkthrough, or the Set-Up Guide — or contact us and we will help you sort it out.
    • Wire your bus bar and breakers before and after the controller, then power up in the right order. Getting the sequence right prevents almost all wiring issues, including the common "spinning but 0 W" problem.
    • Fit a breaker before the controller (turbine/solar side) and after it (battery side), landing on a DC bus bar.
    • Keep the turbine-to-controller cable run to 2–10 metres to limit voltage drop.
    • Power up in this order: battery breaker first, then solar, then wind turbine last.
    • See our full How to Install & Start Up guide for the complete step-by-step walkthrough and wiring diagram.