Wind Turbine FAQs

    • Start with two questions: how much wind your site actually gets, and how much room you have.
    • Vertical turbines (the X-300, H1000 and H2000) start turning at 2 to 2.5 m/s and take wind from any direction, so they keep working where the wind swirls and shifts — around buildings, trees and rooflines. They run from 300 W up to 2000 W.
    • Horizontal turbines (M-400, M-600, M-800, and the L1, L2 and G series) want cleaner, steadier wind and a clear run at it. In clean, steady wind a horizontal of the same rating is usually the better harvester, and they scale further — 400 W up to 5000 W.
    • Match the turbine to your battery bank, not to the biggest number. 12 V suits a camper, 4WD or tinnie; 24 V a van, cabin or boat; 48 V a shed or remote block.
    1. The largest models run at mains voltage, and the L2-3000, G-3000 and G-5000 are ground-mount only — they need a 10–15 m mast and are not rooftop units.
    2. Rated power is measured at 10–14 m/s, depending on the model. What you get at your place depends on your wind, your mast height and the season — not on a number on our website.
    1. No. Wind turbines generate "wild" 3-phase AC power that changes voltage constantly with the wind speed.
    2. Connecting it directly to a battery or a standard solar inverter will destroy your equipment.
    • You must wire the turbine into a dedicated wind charge controller (pure-wind or wind-solar hybrid) with a dump-load resistor.
    • The controller converts the power to stable DC to charge your batteries safely.
  • Match the turbine and its controller to the voltage of your existing battery bank:

    • 12 V: compact mobile setups — caravans, 4WDs and camper trailers.
    • 24 V: medium setups — off-grid sheds, cabins and motorhomes.
    • 48 V: most of this range, and the sensible choice for a full off-grid system. Higher voltage means less current in the cable, so less loss over a long run and lighter cable.
    • When your battery bank is fully charged it stops accepting power.
    1. If a storm hits at night with the batteries full, a turbine with nowhere to send its power will free-spin out of control and can physically fly apart.
    • The controller prevents that by diverting the excess into the dump load resistor, which burns it off safely as heat and acts as an electronic brake to slow the turbine down.
    • Yes, you need one.
    • Usually quieter, but not silent — no turbine is.
    • Why a Horizontal is Louder: its blade tips travel several times faster than the wind, and blade noise climbs steeply with tip speed. The whoosh rises and falls as each blade comes round — a rhythmic swish that carries through wind noise more than a steady hiss does.
    • Why a Vertical is Usually Quieter: its blades turn more slowly, so there is less of that whoosh.
    1. What we won't Tell you: that it's silent. Every turbine gets louder as the wind picks up. The wind often covers much of it in a strong blow, but a close neighbour can still hear one in light to moderate wind.
    2. The manufacturer publishes no noise figure for the turbines themselves (the "65 dB or less" on some Specs tabs is the controller's), so we don't quote one.
    • On a building, use vibration isolators — a turbine bolted to a structure carries its sound into the rooms — and check your council's rules on noise, height and placement before you order a mast.
    • It will turn, but turning is not charging. The blades start turning at 2 to 2.5 m/s (about 7 to 9 km/h) — a light breeze.
    • Charging starts at the cut-in speed: 3 m/s (about 11 km/h) on every model except the X-300, which starts and charges from 2 m/s. Output then climbs steeply with wind speed.
    1. The rated figure is measured much higher — 10 to 14 m/s depending on the model, a 36 to 50 km/h wind, not a normal afternoon. Each product page's spec table gives that model's own numbers.
    • A gentle breeze keeps the turbine ticking over; it takes real wind to push real power into your batteries. Every horizontal model has its measured power curve published on its product page — work from that, not from the number in the product name.
    • Yes — connect the turbine to a battery bank first, through a dedicated charge controller.
    1. Never straight to an inverter. Connecting a wind turbine directly to a standard inverter will damage the equipment or cause the system to fail.

    The Correct Order:

    • 1. Wind Turbine — generates wild, fluctuating 3-phase AC as the wind changes.
    • 2. Hybrid or Wind Charge Controller — converts it to steady DC, and protects the turbine from over-speeding with an electronic brake.
    • 3. Battery Bank (12 V, 24 V or 48 V) — absorbs the gusts and provides a steady source of energy.
    • 4. Off-Grid Inverter — connects to the battery, converting stored DC into AC for your appliances.

    Why you Cannot Skip the Battery:

    1. Unstable Voltage: wind changes second by second. Without a battery to smooth it out, a direct-connected inverter would constantly cut out.
    2. Turbine Damage: when a battery is full or disconnected, the turbine loses its load. Without that resistance the blades can spin out of control in high wind and destroy the unit. The controller uses the battery connection to dump excess power and slow it down.
    1. This turbine generates 3-phase AC power and cannot be connected directly to a battery, a solar controller or a home inverter.
    • It must run through a dedicated wind charge controller (pure-wind or wind-solar hybrid) with a dump-load resistor. The dump load stops the turbine over-speeding and destroying itself in high winds once your batteries are full.
    • Installation and commissioning must be carried out by a suitably qualified and licensed electrician.
    • Cable, breakers, isolators and all protective devices are selected to suit your site and are the electrician's call, not ours.
  • It is almost always one of three installation issues. Check them in order.

    Quick Checks — Tick as You Go

    • Is the Meter Set to AC Volts (V~)?
    • Does it Spin Freely Once Disconnected from the Controller?
    • Is the Cable from the Mast Heavy Enough for the Run?

    1. The Multimeter is Set to DC — The Most Common Mistake.

    1. Measuring the three turbine wires with the meter set to DC volts gives a false reading near zero.
    • Wind turbines generate 3-phase AC directly from the stator. Switch the meter to AC volts (V~).

    2. The Turbine is Stalling Because of a Short.

    1. The blades turn heavily and slowly, or lock up: if any of the three AC output wires touch each other, or the controller's braking diodes have short-circuited, it acts as a magnetic brake — the turbine can never spin fast enough to build voltage.
    • Disconnect the turbine from the controller. If it frees up and spins much faster, the problem is a short in the wiring or a faulty controller.

    3. Voltage Drop from Thin Cable.

    1. Thin solar or automotive cable over 20 metres or more loses the power as heat before it reaches the controller.
    • Use heavy cable between the mast and the controller on long runs — minimum 8 AWG, ideally 6 AWG. Final sizing is your electrician's call.
    • The number in the name is a peak rating, not a promise.
    • A turbine's rated output is measured at a specific wind speed — 10 to 14 m/s depending on the model, which is about 36 to 50 km/h — and most sites see far less than that most of the time.
    • Your display shows what the wind is delivering right now, so it will sit well below the rated figure and move second by second as the wind changes. That is physics, not a fault.
    • As an example, the L2-2500 is rated 2,500 W at 11 m/s. On a decent steady coastal breeze of 7 m/s the manufacturer's own curve gives about 813 W. That is why we publish the full power curve on every horizontal turbine's product page.
    • Where these machines earn their keep is time: they keep charging through the night and through the weather that shuts solar down.
    1. If the display shows 0 W while the blades are spinning, that is a different problem — see the 0 W question.
    • Not necessarily — this is one of the most common questions we get, and it is rarely a faulty unit.
    • It is usually a quick settings check, or (on a first-time install) how the wiring and start-up sequence were done.
    • See our full Wind Turbine 0W Troubleshooting Guide for the complete walkthrough, or the Set-Up Guide — or contact us and we will help you sort it out.
    • Wire your bus bar and breakers before and after the controller, then power up in the right order. Getting the sequence right prevents almost all wiring issues, including the common "spinning but 0 W" problem.
    • Fit a breaker before the controller (turbine/solar side) and after it (battery side), landing on a DC bus bar.
    • Keep the turbine-to-controller cable run to 2–10 metres to limit voltage drop.
    • Power up in this order: battery breaker first, then solar, then wind turbine last.
    • See our full How to Install & Start Up guide for the complete step-by-step walkthrough and wiring diagram.

Low-RPM Wind Turbine Permanent Magnet Generator 12V 24V 48V

Regular price $690.00 AUD
Package
Maker's Rating
Voltage

Delivering Outside Australia or New Zealand? Delivery is free. Import duty, customs charges and any tax on arrival are set by your country and are payable by you — we can’t collect them for you.

Tracking

Keep an Eye on your Gear

Simply enter the tracking number sent to your email to see exactly where your package is and when it is estimated to arrive.

Note: It may take 24-48 hours for tracking information to update after your order has been dispatched.

Track my Order

Rated by the Maker at 500 RPM. Match your Rotor to it.

Build your own vertical wind turbine and the generator is the part you can't knock up in the shed. Blades, a frame and a pole you can fabricate. A generator that still makes useful charge at the slow speed a vertical rotor actually turns is the bit you have to buy.

This is a three-phase permanent magnet generator, sold as the generator only. The maker rates it at 500 W, 1000 W, 2000 W or 3000 W, all at 500 RPM, and each size comes wound for a 12V, 24V or 48V battery bank. Pick the winding that matches the bank you already have, because it is set at the factory and can't be changed later.

Be clear on what it is not. There are no blades, no tail, no pole and no controller in the box. The output is unregulated three-phase AC that rises and falls with rotor speed, so it has to go through a wind or hybrid charge controller before it reaches a battery. The wattage is the maker's rating at 500 RPM, not a figure we have tested — a slow rotor in light wind spends most of its life well below that, so treat it as a ceiling, not an average.

Delivery is free. It ships from the supplier overseas, and their own estimate is about 17 to 28 days from the day you order to Australia, and about 15 to 29 days to New Zealand. That is slower than most of our range, and we'd rather you knew before you order.

What it Solves
  • Home-Built Vertical Turbine: you've built a rotor that turns slowly and need a direct-drive head that charges without a gearbox in the way.
  • Repowering a Small Turbine: the frame and blades are fine but the original head is finished, and you want to stay on the same battery voltage.
  • Shack, Hut or Mooring: somewhere you only visit some weekends, where the bank needs topping up while nobody's there.
  • Shed & Workshop Bank: a shed a long way from the meter box, charging a small battery bank off your own build.
  • Test Rig or Training Bench: a workshop, school or hobby project that needs a real three-phase generator to put on a bench.
Key Features
  • Permanent Magnet Field: rare-earth NdFeB magnets, as stated by the supplier, so there is no field winding to energise and no brushes to wear.
  • Gearless Direct Drive: the rotor drives the generator directly, with no step-up gearbox to oil or replace.
  • Rated at 500 RPM: the maker's rated speed. The wattage on each size is the maker's figure at that speed.
  • Four Sizes: the maker rates them at 500 W, 1000 W, 2000 W and 3000 W.
  • Three Battery Voltages: 12V, 24V and 48V windings, chosen at order. The winding is fixed — you can't reconfigure it on site.
  • Three-Phase Output: unregulated AC out to a wind or hybrid charge controller, which turns it into DC your bank can take.
  • Aluminium Alloy Case: an aluminium alloy case on an iron shaft, as stated by the supplier.
  • Outer-Rotor Layout: the maker describes it as an outer-rotor design, with a bolt-hole flange on the face of the case.
Where This Fits

This is one part of the gear that sits between a wind turbine and your battery bank. Here's the whole picture:

Off-grid wiring layout — vertical axis wind turbine and solar panel into a hybrid MPPT controller, with dump load, main battery circuit breaker, DC bus bar, 12V 24V 48V battery bank and inverter

Every input and output wants a breaker or isolator on it, so you can safely shut down and isolate the turbine before you touch anything. That protects you, and it stops a surge damaging your new turbine or the rest of your power system. Cable sizing depends on your run length, voltage and current — if you're building 12V or 24V, check the sizing against your own run or ask your sparky.

Q & A

Can I Wire This Straight to my Battery Bank?

No. It puts out unregulated three-phase AC that varies with rotor speed, so it needs a wind or hybrid charge controller in between. Have a look at the hybrid MPPT controllers — the controller also brakes the turbine once the bank is full, which the generator can't do on its own.

Which Voltage Should I Order — 12V, 24V or 48V?

Match the bank you're charging. The winding is set at the factory, so this isn't a switch you flick later. On the 2000 W and 3000 W sizes, 48V is the easier system to wire — the current is lower, so the cable and breakers are smaller.

Will it Actually Make its Rated Wattage?

The wattage is the maker's rating at 500 RPM, and we haven't tested it. Below that speed the output falls away, and a vertical rotor in light wind spends a lot of its life well below rated speed. Size your bank on what you realistically expect over a day, not on the number in the option.

How do I Attach my Rotor?

The supplier doesn't publish the shaft diameter, keyway or flange bolt pattern, and we're not going to guess a figure you'd machine to. The photos show a shaft out of the centre and a bolt-hole flange on the face of the case, and the maker calls it an outer-rotor design. Measure it when it arrives before you cut any metal.

Does it Come with a Mounting Base?

We can't promise one. The supplier's spec list mentions a mounting base, but their picture for this option shows the generator without one. Plan your own mount.

What Colour is it?

The supplier's photos show the same generator in silver and in white, and their picture for this option is silver. The colour that ships is not specified.

Is it Weatherproof Enough to Sit on a Pole?

No water rating is published, so don't assume it will shrug off weather. Plan on a housing that keeps direct rain off it and lets it drain and breathe, the same as you would for any generator head.

How Long will Delivery Take?

Delivery is free. It comes from the supplier overseas, and their own estimate is about 17 to 28 days from the day you order to Australia, and about 15 to 29 days to New Zealand. Outside Australia, any import duty or tax charged on arrival is yours.

Specs

Specification Detail
Generator Type Three-phase permanent magnet synchronous generator, gearless direct drive (the maker's description)
Maker's Model Codes CF-500, CF-1000, CF-2000, CF-3000
Rated Power 500 W, 1000 W, 2000 W or 3000 W — the maker's ratings at 500 RPM, not tested by us
Rated Speed 500 RPM, as rated by the maker
Battery Voltage Options 12V, 24V or 48V — winding set at the factory, not switchable
Winding Connection Star (Y), as printed by the maker
Output Type Unregulated three-phase AC — needs a wind or hybrid charge controller
Construction Outer rotor, as described by the maker
Magnets Rare-earth NdFeB, as stated by the supplier
Case & Shaft Aluminium alloy case, iron shaft, as stated by the supplier
Weight 4.2 kg (500 W and 1000 W), 7 kg (2000 W and 3000 W), as printed on the maker's spec sheet
Diameter Not confirmed — the maker's sheet prints 160 mm, 161 mm, 200 mm and 200 mm without saying what is measured
Shaft Diameter & Keyway Not Specified by Supplier
Flange Bolt Pattern Not Specified by Supplier
Mounting Base Not confirmed for this option — the supplier's picture shows no base
Starting Torque Not specified — the maker prints "<0.1" with no unit
Cut-in Speed Not Specified by Supplier
Rated Output Current Not Specified by Supplier
Operating Temperature -40°C to +80°C, as printed by the maker
Ingress Protection (IP) Rating Not specified. Keep direct rain off it
Certification None we can verify — no marking shown on the generator
In the Box Generator only. No blades, tail, pole or controller; a mounting base is not confirmed
Delivery Free. About 17 to 28 days from order to Australia and about 15 to 29 days to New Zealand (the supplier's estimate)
Turbine Spinning but Showing 0W?

It is almost never a faulty turbine or controller. Read the 0W troubleshooting & correct installation guide before you assume something is broken.

Watch Me

Everything we know about this one is written down: the Specs for the supplier's published figures, and the Q & A for the questions buyers ask before they order.

Payment & Security

Payment Methods

  • American Express
  • Apple Pay
  • Google Pay
  • Mastercard
  • PayPal
  • Visa

Your payment information is processed securely.

We do not store credit card details or have access to your credit card information.

Wind Turbine FAQs

    • Start with two questions: how much wind your site actually gets, and how much room you have.
    • Vertical turbines (the X-300, H1000 and H2000) start turning at 2 to 2.5 m/s and take wind from any direction, so they keep working where the wind swirls and shifts — around buildings, trees and rooflines. They run from 300 W up to 2000 W.
    • Horizontal turbines (M-400, M-600, M-800, and the L1, L2 and G series) want cleaner, steadier wind and a clear run at it. In clean, steady wind a horizontal of the same rating is usually the better harvester, and they scale further — 400 W up to 5000 W.
    • Match the turbine to your battery bank, not to the biggest number. 12 V suits a camper, 4WD or tinnie; 24 V a van, cabin or boat; 48 V a shed or remote block.
    1. The largest models run at mains voltage, and the L2-3000, G-3000 and G-5000 are ground-mount only — they need a 10–15 m mast and are not rooftop units.
    2. Rated power is measured at 10–14 m/s, depending on the model. What you get at your place depends on your wind, your mast height and the season — not on a number on our website.
    1. No. Wind turbines generate "wild" 3-phase AC power that changes voltage constantly with the wind speed.
    2. Connecting it directly to a battery or a standard solar inverter will destroy your equipment.
    • You must wire the turbine into a dedicated wind charge controller (pure-wind or wind-solar hybrid) with a dump-load resistor.
    • The controller converts the power to stable DC to charge your batteries safely.
  • Match the turbine and its controller to the voltage of your existing battery bank:

    • 12 V: compact mobile setups — caravans, 4WDs and camper trailers.
    • 24 V: medium setups — off-grid sheds, cabins and motorhomes.
    • 48 V: most of this range, and the sensible choice for a full off-grid system. Higher voltage means less current in the cable, so less loss over a long run and lighter cable.
    • When your battery bank is fully charged it stops accepting power.
    1. If a storm hits at night with the batteries full, a turbine with nowhere to send its power will free-spin out of control and can physically fly apart.
    • The controller prevents that by diverting the excess into the dump load resistor, which burns it off safely as heat and acts as an electronic brake to slow the turbine down.
    • Yes, you need one.
    • Usually quieter, but not silent — no turbine is.
    • Why a Horizontal is Louder: its blade tips travel several times faster than the wind, and blade noise climbs steeply with tip speed. The whoosh rises and falls as each blade comes round — a rhythmic swish that carries through wind noise more than a steady hiss does.
    • Why a Vertical is Usually Quieter: its blades turn more slowly, so there is less of that whoosh.
    1. What we won't Tell you: that it's silent. Every turbine gets louder as the wind picks up. The wind often covers much of it in a strong blow, but a close neighbour can still hear one in light to moderate wind.
    2. The manufacturer publishes no noise figure for the turbines themselves (the "65 dB or less" on some Specs tabs is the controller's), so we don't quote one.
    • On a building, use vibration isolators — a turbine bolted to a structure carries its sound into the rooms — and check your council's rules on noise, height and placement before you order a mast.
    • It will turn, but turning is not charging. The blades start turning at 2 to 2.5 m/s (about 7 to 9 km/h) — a light breeze.
    • Charging starts at the cut-in speed: 3 m/s (about 11 km/h) on every model except the X-300, which starts and charges from 2 m/s. Output then climbs steeply with wind speed.
    1. The rated figure is measured much higher — 10 to 14 m/s depending on the model, a 36 to 50 km/h wind, not a normal afternoon. Each product page's spec table gives that model's own numbers.
    • A gentle breeze keeps the turbine ticking over; it takes real wind to push real power into your batteries. Every horizontal model has its measured power curve published on its product page — work from that, not from the number in the product name.
    • Yes — connect the turbine to a battery bank first, through a dedicated charge controller.
    1. Never straight to an inverter. Connecting a wind turbine directly to a standard inverter will damage the equipment or cause the system to fail.

    The Correct Order:

    • 1. Wind Turbine — generates wild, fluctuating 3-phase AC as the wind changes.
    • 2. Hybrid or Wind Charge Controller — converts it to steady DC, and protects the turbine from over-speeding with an electronic brake.
    • 3. Battery Bank (12 V, 24 V or 48 V) — absorbs the gusts and provides a steady source of energy.
    • 4. Off-Grid Inverter — connects to the battery, converting stored DC into AC for your appliances.

    Why you Cannot Skip the Battery:

    1. Unstable Voltage: wind changes second by second. Without a battery to smooth it out, a direct-connected inverter would constantly cut out.
    2. Turbine Damage: when a battery is full or disconnected, the turbine loses its load. Without that resistance the blades can spin out of control in high wind and destroy the unit. The controller uses the battery connection to dump excess power and slow it down.
    1. This turbine generates 3-phase AC power and cannot be connected directly to a battery, a solar controller or a home inverter.
    • It must run through a dedicated wind charge controller (pure-wind or wind-solar hybrid) with a dump-load resistor. The dump load stops the turbine over-speeding and destroying itself in high winds once your batteries are full.
    • Installation and commissioning must be carried out by a suitably qualified and licensed electrician.
    • Cable, breakers, isolators and all protective devices are selected to suit your site and are the electrician's call, not ours.
  • It is almost always one of three installation issues. Check them in order.

    Quick Checks — Tick as You Go

    • Is the Meter Set to AC Volts (V~)?
    • Does it Spin Freely Once Disconnected from the Controller?
    • Is the Cable from the Mast Heavy Enough for the Run?

    1. The Multimeter is Set to DC — The Most Common Mistake.

    1. Measuring the three turbine wires with the meter set to DC volts gives a false reading near zero.
    • Wind turbines generate 3-phase AC directly from the stator. Switch the meter to AC volts (V~).

    2. The Turbine is Stalling Because of a Short.

    1. The blades turn heavily and slowly, or lock up: if any of the three AC output wires touch each other, or the controller's braking diodes have short-circuited, it acts as a magnetic brake — the turbine can never spin fast enough to build voltage.
    • Disconnect the turbine from the controller. If it frees up and spins much faster, the problem is a short in the wiring or a faulty controller.

    3. Voltage Drop from Thin Cable.

    1. Thin solar or automotive cable over 20 metres or more loses the power as heat before it reaches the controller.
    • Use heavy cable between the mast and the controller on long runs — minimum 8 AWG, ideally 6 AWG. Final sizing is your electrician's call.
    • The number in the name is a peak rating, not a promise.
    • A turbine's rated output is measured at a specific wind speed — 10 to 14 m/s depending on the model, which is about 36 to 50 km/h — and most sites see far less than that most of the time.
    • Your display shows what the wind is delivering right now, so it will sit well below the rated figure and move second by second as the wind changes. That is physics, not a fault.
    • As an example, the L2-2500 is rated 2,500 W at 11 m/s. On a decent steady coastal breeze of 7 m/s the manufacturer's own curve gives about 813 W. That is why we publish the full power curve on every horizontal turbine's product page.
    • Where these machines earn their keep is time: they keep charging through the night and through the weather that shuts solar down.
    1. If the display shows 0 W while the blades are spinning, that is a different problem — see the 0 W question.
    • Not necessarily — this is one of the most common questions we get, and it is rarely a faulty unit.
    • It is usually a quick settings check, or (on a first-time install) how the wiring and start-up sequence were done.
    • See our full Wind Turbine 0W Troubleshooting Guide for the complete walkthrough, or the Set-Up Guide — or contact us and we will help you sort it out.
    • Wire your bus bar and breakers before and after the controller, then power up in the right order. Getting the sequence right prevents almost all wiring issues, including the common "spinning but 0 W" problem.
    • Fit a breaker before the controller (turbine/solar side) and after it (battery side), landing on a DC bus bar.
    • Keep the turbine-to-controller cable run to 2–10 metres to limit voltage drop.
    • Power up in this order: battery breaker first, then solar, then wind turbine last.
    • See our full How to Install & Start Up guide for the complete step-by-step walkthrough and wiring diagram.