2pcs Anderson Plug 3Pin 50A 75A 175A Quick Connect Kit
Delivering Outside Australia or New Zealand? Delivery is free. Import duty, customs charges and any tax on arrival are set by your country and are payable by you — we can’t collect them for you.
Tracking
Tracking
Keep an Eye on your Gear
Simply enter the tracking number sent to your email to see exactly where your package is and when it is estimated to arrive.
Note: It may take 24-48 hours for tracking information to update after your order has been dispatched.
Unplug it Instead of Cutting it.
Anything you might one day need to disconnect should have a plug on it. A turbine you have to lower for maintenance, a van that comes off the tow, a battery bank you swap out, a generator you wheel in and out. Hard-wire those and every disconnection means undoing lugs in an awkward spot, usually in bad light.
These are 3-pin quick connects with silver-plated copper terminals, rated to 600V, in 50A, 75A and 175A. Pull them apart with one hand and the connection is broken cleanly, with no exposed lugs to short across.
They are genderless — there is no plug and socket, just two identical halves that mate together. One part number, no wrong end, and a spare always fits.
What it Solves
- Drop the Turbine Without an Electrical Job: a plug at the base of the pole means lowering it for maintenance is a two-minute disconnect, not a rewire.
- Take the Power System Off the Van: unplug rather than unbolt when the setup moves between vehicle, camp and shed.
- Swap a Battery Bank Without Cutting Cable: the connector stays, the bank changes.
- Colour-Code So Nothing Gets Crossed: grey and red shells will not mate with each other, so a 12V feed cannot be plugged into a 48V one by accident.
- Keep a Safe End on a Live Cable: a disconnected half has recessed contacts rather than bare lug hanging out of a loom.
Key Features
- Three Current Ratings: 50A, 75A and 175A, so you can match the connector to the run rather than over- or under-buying.
- Rated 600V: well clear of anything a 12V, 24V or 48V system will present.
- Silver-Plated Copper Terminals: silver has the lowest contact resistance of any metal, which is what keeps a repeatedly-mated joint cool.
- Genderless Housings: two identical halves mate together. No male and female to keep track of.
- Takes 4 mm² to 50 mm² Cable: depending on the amperage chosen.
- −20°C to +105°C: handles an engine bay as well as a cold morning.
- Grey & Red Shells: same colour mates with same colour, so different circuits stay separate.
- Two per Pack: a mating pair, which is what a single connection actually needs.
- Delivery: Free Standard Delivery, 5 to 10 working days from the day you order. Allow 1–2 days for fulfilment. Regional and remote addresses can take longer.
Where This Fits
A quick connect is one part of the gear that sits between a wind turbine and your battery bank. Here is the whole picture:

- Wind Turbines: vertical and horizontal turbines from 300 W to 5 kW (rated). Fit a connector at the base of the pole and dropping the turbine stops being an electrical job.
- Hybrid MPPT Controllers: you cannot wire a turbine straight to a battery. The controller rectifies the output, manages the charge, and brakes the turbine when the bank is full.
- The Rest of the Electrical Range: bus bars, breakers, isolators, cable and lugs.
Every input and output wants a breaker or isolator on it, so you can safely shut down and isolate the turbine before you touch anything. A quick connect is a convenience, not protection — it is not a substitute for a breaker. Cable sizing depends on run length, voltage and current, so check it against your own run or ask your sparky, and keep the invoice, because our warranty on electrical items asks for proof of professional installation.
Q & A
Which Amperage Should I Choose?
Match it to the current the circuit actually carries and the cable you are terminating, then leave headroom. 50A suits accessory and smaller charging runs, 175A suits heavy battery-to-inverter or main feeds. The connector should never be the weakest link in the run.
Can I Unplug it While Current is Flowing?
Don't. These are connectors, not load-break switches — pulling them under load draws an arc that pits the contacts and can burn you. Shut the circuit down at the breaker or isolator first, then unplug. That is exactly why every input and output should have an isolator on it.
Why Grey and Red if they are Genderless?
The housings only mate with the same colour. That is deliberate keying — it stops someone plugging a 12V accessory circuit into a 48V feed. Use a different colour for each voltage or circuit type.
What is the Third Pin for?
These are the 3-pin version, which gives an extra conductor over the common 2-pin type — useful for an earth, a sense wire or a third phase. If you only need positive and negative, you simply do not populate the third.
Do I Need to Solder or Crimp them?
Crimping with the correct die is the standard method and gives the most reliable joint. Soldering is possible but a soldered joint goes brittle where it meets the flex. Whichever you use, the terminal must be fully seated so it clicks into the housing.
Are These Genuine Anderson Brand?
They are Anderson-style connectors of the same pattern, not specified by supplier as genuine Anderson Power Products. They mate with connectors of the same type and rating.
Specs
| Product Type | Anderson-Style Genderless DC Quick Connector, 3 pin |
| Current Ratings | 50A, 75A or 175A, Depending on Option |
| Rated Voltage | 600V |
| Pins | 3P |
| Terminal Material | Silver-Plated Copper |
| Cable Range | 4 mm² to 50 mm², Depending on Amperage |
| Operating Temperature | −20°C to +105°C |
| Shell Colours | Grey & red. Same colour mates with same colour only |
| Configuration | Genderless — Two Identical Halves Mate Together |
| Quantity | 2 per Pack (A Mating Pair) |
| Termination | Crimp, or Solder |
| Load Breaking | Not a Load-Break Connector — Isolate the Circuit Before Unplugging |
| Ingress Rating | Not Specified by Supplier |
| Dimensions | Not Specified by Supplier |
| Brand | Anderson-style. Not specified by supplier as genuine Anderson Power Products |
Watch Me
No video on this one. If you are wiring an off-grid system, these two guides cover the sequence and the hazards:
- How to install and start up a wind turbine — the correct order of connection, and the two shock hazards to know first.
- Wind turbine spinning but showing 0W — nearly always wiring or setup rather than faulty gear.
Payment & Security
Payment Methods
Your payment information is processed securely.
We do not store credit card details or have access to your credit card information.
Wind Turbine FAQs
-
- Start with two questions: how much wind your site actually gets, and how much room you have.
- Vertical turbines (the X-300, H1000 and H2000) start turning at 2 to 2.5 m/s and take wind from any direction, so they keep working where the wind swirls and shifts — around buildings, trees and rooflines. They run from 300 W up to 2000 W.
- Horizontal turbines (M-400, M-600, M-800, and the L1, L2 and G series) want cleaner, steadier wind and a clear run at it. In clean, steady wind a horizontal of the same rating is usually the better harvester, and they scale further — 400 W up to 5000 W.
- Match the turbine to your battery bank, not to the biggest number. 12 V suits a camper, 4WD or tinnie; 24 V a van, cabin or boat; 48 V a shed or remote block.
- The largest models run at mains voltage, and the L2-3000, G-3000 and G-5000 are ground-mount only — they need a 10–15 m mast and are not rooftop units.
- Rated power is measured at 10–14 m/s, depending on the model. What you get at your place depends on your wind, your mast height and the season — not on a number on our website.
-
- No. Wind turbines generate "wild" 3-phase AC power that changes voltage constantly with the wind speed.
- Connecting it directly to a battery or a standard solar inverter will destroy your equipment.
- You must wire the turbine into a dedicated wind charge controller (pure-wind or wind-solar hybrid) with a dump-load resistor.
- The controller converts the power to stable DC to charge your batteries safely.
-
Match the turbine and its controller to the voltage of your existing battery bank:
- 12 V: compact mobile setups — caravans, 4WDs and camper trailers.
- 24 V: medium setups — off-grid sheds, cabins and motorhomes.
- 48 V: most of this range, and the sensible choice for a full off-grid system. Higher voltage means less current in the cable, so less loss over a long run and lighter cable.
-
- When your battery bank is fully charged it stops accepting power.
- If a storm hits at night with the batteries full, a turbine with nowhere to send its power will free-spin out of control and can physically fly apart.
- The controller prevents that by diverting the excess into the dump load resistor, which burns it off safely as heat and acts as an electronic brake to slow the turbine down.
- Yes, you need one.
-
- Usually quieter, but not silent — no turbine is.
- Why a Horizontal is Louder: its blade tips travel several times faster than the wind, and blade noise climbs steeply with tip speed. The whoosh rises and falls as each blade comes round — a rhythmic swish that carries through wind noise more than a steady hiss does.
- Why a Vertical is Usually Quieter: its blades turn more slowly, so there is less of that whoosh.
- What we won't Tell you: that it's silent. Every turbine gets louder as the wind picks up. The wind often covers much of it in a strong blow, but a close neighbour can still hear one in light to moderate wind.
- The manufacturer publishes no noise figure for the turbines themselves (the "65 dB or less" on some Specs tabs is the controller's), so we don't quote one.
- On a building, use vibration isolators — a turbine bolted to a structure carries its sound into the rooms — and check your council's rules on noise, height and placement before you order a mast.
-
- It will turn, but turning is not charging. The blades start turning at 2 to 2.5 m/s (about 7 to 9 km/h) — a light breeze.
- Charging starts at the cut-in speed: 3 m/s (about 11 km/h) on every model except the X-300, which starts and charges from 2 m/s. Output then climbs steeply with wind speed.
- The rated figure is measured much higher — 10 to 14 m/s depending on the model, a 36 to 50 km/h wind, not a normal afternoon. Each product page's spec table gives that model's own numbers.
- A gentle breeze keeps the turbine ticking over; it takes real wind to push real power into your batteries. Every horizontal model has its measured power curve published on its product page — work from that, not from the number in the product name.
-
- No — small turbines are built to spin fast. The smaller the rotor, the faster it has to turn to keep its blade tips up with the wind: the M-400's 1.35 m rotor runs at about 800 rpm, the M-600 and M-800 at about 500, the big G-series at 300.
- In the manufacturer's words, the high rpm is a design necessity, not a defect. A slower generator would need a bigger stator and more magnets and copper — heavier and dearer.
- They start turning at 2 to 2.5 m/s and make power right across the wind range — just less when the wind is light. What you get depends on your site and how high you mount it.
-
- Yes — connect the turbine to a battery bank first, through a dedicated charge controller.
- Never straight to an inverter. Connecting a wind turbine directly to a standard inverter will damage the equipment or cause the system to fail.
The Correct Order:
- 1. Wind Turbine — generates wild, fluctuating 3-phase AC as the wind changes.
- 2. Hybrid or Wind Charge Controller — converts it to steady DC, and protects the turbine from over-speeding with an electronic brake.
- 3. Battery Bank (12 V, 24 V or 48 V) — absorbs the gusts and provides a steady source of energy.
- 4. Off-Grid Inverter — connects to the battery, converting stored DC into AC for your appliances.
Why you Cannot Skip the Battery:
- Unstable Voltage: wind changes second by second. Without a battery to smooth it out, a direct-connected inverter would constantly cut out.
- Turbine Damage: when a battery is full or disconnected, the turbine loses its load. Without that resistance the blades can spin out of control in high wind and destroy the unit. The controller uses the battery connection to dump excess power and slow it down.
-
- This turbine generates 3-phase AC power and cannot be connected directly to a battery, a solar controller or a home inverter.
- It must run through a dedicated wind charge controller (pure-wind or wind-solar hybrid) with a dump-load resistor. The dump load stops the turbine over-speeding and destroying itself in high winds once your batteries are full.
- Installation and commissioning must be carried out by a suitably qualified and licensed electrician.
- Cable, breakers, isolators and all protective devices are selected to suit your site and are the electrician's call, not ours.
-
It is almost always one of three installation issues. Check them in order.
Quick Checks — Tick as You Go
- Is the Meter Set to AC Volts (V~)?
- Does it Spin Freely Once Disconnected from the Controller?
- Is the Cable from the Mast Heavy Enough for the Run?
1. The Multimeter is Set to DC — The Most Common Mistake.
- Measuring the three turbine wires with the meter set to DC volts gives a false reading near zero.
- Wind turbines generate 3-phase AC directly from the stator. Switch the meter to AC volts (V~).
2. The Turbine is Stalling Because of a Short.
- The blades turn heavily and slowly, or lock up: if any of the three AC output wires touch each other, or the controller's braking diodes have short-circuited, it acts as a magnetic brake — the turbine can never spin fast enough to build voltage.
- Disconnect the turbine from the controller. If it frees up and spins much faster, the problem is a short in the wiring or a faulty controller.
3. Voltage Drop from Thin Cable.
- Thin solar or automotive cable over 20 metres or more loses the power as heat before it reaches the controller.
- Use heavy cable between the mast and the controller on long runs — minimum 8 AWG, ideally 6 AWG. Final sizing is your electrician's call.
-
- The number in the name is a peak rating, not a promise.
- A turbine's rated output is measured at a specific wind speed — 10 to 14 m/s depending on the model, which is about 36 to 50 km/h — and most sites see far less than that most of the time.
- Your display shows what the wind is delivering right now, so it will sit well below the rated figure and move second by second as the wind changes. That is physics, not a fault.
- As an example, the L2-2500 is rated 2,500 W at 11 m/s. On a decent steady coastal breeze of 7 m/s the manufacturer's own curve gives about 813 W. That is why we publish the full power curve on every horizontal turbine's product page.
- Where these machines earn their keep is time: they keep charging through the night and through the weather that shuts solar down.
- If the display shows 0 W while the blades are spinning, that is a different problem — see the 0 W question.
-
- Not necessarily — this is one of the most common questions we get, and it is rarely a faulty unit.
- It is usually a quick settings check, or (on a first-time install) how the wiring and start-up sequence were done.
- See our full Wind Turbine 0W Troubleshooting Guide for the complete walkthrough, or the Set-Up Guide — or contact us and we will help you sort it out.
-
- Wire your bus bar and breakers before and after the controller, then power up in the right order. Getting the sequence right prevents almost all wiring issues, including the common "spinning but 0 W" problem.
- Fit a breaker before the controller (turbine/solar side) and after it (battery side), landing on a DC bus bar.
- Keep the turbine-to-controller cable run to 2–10 metres to limit voltage drop.
- Power up in this order: battery breaker first, then solar, then wind turbine last.
- See our full How to Install & Start Up guide for the complete step-by-step walkthrough and wiring diagram.